100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

GS-CMD1 Carbon Monoxide Sensor (wall Mounted)

GS-CMD1 Carbon Monoxide Sensor (wall mounted)
£17000

(£204.00 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:GS-CMD1

Description

The CMD series carbon monoxide detector uses an electrochemical sensor to monitor the carbon monoxide level and outputs a factory calibrated 4-20 mA or 0-10 Vdc (Please specify on any order), or optional Modbus signal. Optionally, the device may be  configured with an alarm relay. For the options, please also see recommended products section below.

 

 

Features

  • 0-300 ppm CO range
  • Electrochemical sensing element
  • 4-20 mA or 0-10Vdc output, 2 wire (looped powered) or 3 wire
  • Powered by either AC or DC source
  • Optional on board relay
  • Easy to calibrate in the field

Specifications

  • MEASUREMENT Electrochemical
  • SAMPLE METHOD Diffusion
  • MEASUREMENT RANGE
    Analog: 0-300 ppm
    Modbus: 0-500 ppm
  • ACCURACY ±5 ppm or ±5% of reading (whichever is greater)
    0 to 50°C (32 to 122°F), 15 to 95 %RH
  • AGENCY APPROVALS Sensor is UL Recognized for ASNI/UL-2034 and UL-2075, E240671
  • OPERATING CONDITIONS -20 to 50°C (-4 to 122°F), 15 to 90 %RH, 0.9-1.1 atm
  • STABILITY <5% signal loss/year
  • RESPONSE TIME <35 seconds for 90% step change
  • LIFE EXPECTANCY 7 years in air
  • TYPICAL COVERAGE AREA 700m2 (7500ft2 ) or 15m (50ft) radius
  • WIRING CONNECTIONS Screw terminal block (14 to 22 AWG)
  • ENCLOSURE ABS, UL94-V, IP65 (NEMA 4X)
  • ENCLOSURE DIMENSIONS 71mm W x 104mm H x 48mm D (2.8” x 4.1” x 1.9”)
  • COUNTRY OF ORIGIN Canada
  • NON-RELAY MODEL
    Power Supply: 24 Vdc ±20% or 24 Vac ± 10% (non-isolated half-wave rectified)
    Consumption: 20 mA max
    Output Signal: 4-20 mA loop-powered or 0-10 Vdc (factory calibrated)
    Output Drive Capability @ 24 Vdc: Current - 550Ω max, Voltage - 10,000Ω min
  • RELAY MODEL
    Power Supply: 24 Vdc ±20% or 24 Vdc ±10% (non-isolated half-wave rectified)
    Consumption: 40 mA max
    Output Signal: 4-20 mA sourcing or 0-10 Vdc (factory calibrated)
    Output Drive Capability @ 24 Vdc:, Current - 550Ω max, Voltage - 10,000Ω min
  • Relay Contacts: Form C contacts (N.O. and N.C.), 5 Amps @ 250 Vac, 5 Amps @ 30 Vdc
  • Relay Trip Point: 25, 60 and 150 ppm - jumper selectable
  • Relay Hysteresis: 3% or 9 ppm

Description

The CMD series carbon monoxide detector uses an electrochemical sensor to monitor the carbon monoxide level and outputs a factory calibrated 4-20 mA or 0-10 Vdc (Please specify on any order), or optional Modbus signal. Optionally, the device may be  configured with an alarm relay. For the options, please also see recommended products section below.

 

 

Features

Specifications

Technical

GS-CMD1 Carbon Monoxide sensor datasheet