| LC-101H | LC-102H | LC-103H | |
|---|---|---|---|
| Digital Input | 1 | 2 | 1 |
| Relay Output | 1 | 2 | 3 |
| Max. Load Current |
30 A (Resistive Load, recommend working current is 1.0 A with 220 VAC) |
16 A (Resistive Load, recommend working current is 1.5 A with 220 VAC) |
|
| Max. Lighting Loads |
(1) Incandescent Lamp: 6 units (2) LED(Electronic ballast): 8 units |
(1) Incandescent Lamp: 8 units (2) LED(Electronic ballast): 10 units |
|
| Load Current Readback | Yes. | No | |
| AC Load Current Measurement | 0 ~ 5 A | No | |
| Function | Local and Remote Direct Control Relay ON/OFF and Remote Status Monitoring | ||
| Software | |
|---|---|
| Function | Local and Remote Direct Control Relay ON/OFF and Remote Status Monitoring |
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | ±4 kV for Power |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal |
| Surge (IEC 61000-4-5) | ±2 kV for Power |
| LED Indicators | |
|---|---|
| Status | 1 LED as Power Indicator |
| Digital Input | |
|---|---|
| Channels | 1 |
| Type | Wet Contact, 90 ~ 240 VAC |
| ON Voltage Level | 65 VAC |
| OFF Voltage Level | 56 VAC |
| Isolation | 3000 VDC |
| Input Impedance | 68 KΩ, 2W |
| Relay Output | |
|---|---|
| Channels | 1 |
| Type | Power Relay, Form C (SPDT N.O+N.C..) |
| Contact Rating | 30 A @ 250 VAC |
| AC Load Current Measurement | Yes, 0 ~ 5 A range with 3% of FSR Accuracy. |
| Operate Time | 15 ms Max |
| Release Time | 22 ms Max. |
| Electrical Endurance | 100,000 ops. |
| Mechanical Endurance | 10,000,000 ops |
| Power on Value | Yes |
| Safe Value | Yes |
| Application Specification |
(1).Incandescent Lamp: 40W/ 220VAC * 5 Sets (2).LED(Electronic ballast): 40W/ 220VAC *8 Sets |
| Ethernet | |
|---|---|
| Node Address | 32 to 63 for hardware configuration |
| COM Ports | |
|---|---|
| Ports | 1 x RS-485 |
| Baud Rate |
Hardware Configuration: Fixed 9600 bps Software Configuration: 1200 to 115200 bps |
| Data Format | N,8,1/O,8,1/E,8,1/N,8,2 |
| Protocol | Modbus RTU/DCON |
| Power | |
|---|---|
| Reverse Polarity Protection | Yes |
| Input Range | 10 ~ 30 VDC |
| Consumption | 1.9 W Max. |
| Mechanical | |
|---|---|
| Dimensions (mm) | 72 mm x 95 mm x 57 mm |
| Installation | DIN-Rail |
| Environment | |
|---|---|
| Operating Temperature | -25 ~ +75°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 95% RH, Non-condensing |

| LC-101H | LC-102H | LC-103H | |
|---|---|---|---|
| Digital Input | 1 | 2 | 1 |
| Relay Output | 1 | 2 | 3 |
| Max. Load Current |
30 A (Resistive Load, recommend working current is 1.0 A with 220 VAC) |
16 A (Resistive Load, recommend working current is 1.5 A with 220 VAC) |
|
| Max. Lighting Loads |
(1) Incandescent Lamp: 6 units (2) LED(Electronic ballast): 8 units |
(1) Incandescent Lamp: 8 units (2) LED(Electronic ballast): 10 units |
|
| Load Current Readback | Yes. | No | |
| AC Load Current Measurement | 0 ~ 5 A | No | |
| Function | Local and Remote Direct Control Relay ON/OFF and Remote Status Monitoring | ||
| Software | |
|---|---|
| Function | Local and Remote Direct Control Relay ON/OFF and Remote Status Monitoring |
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | ±4 kV for Power |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal |
| Surge (IEC 61000-4-5) | ±2 kV for Power |
| LED Indicators | |
|---|---|
| Status | 1 LED as Power Indicator |
| Digital Input | |
|---|---|
| Channels | 1 |
| Type | Wet Contact, 90 ~ 240 VAC |
| ON Voltage Level | 65 VAC |
| OFF Voltage Level | 56 VAC |
| Isolation | 3000 VDC |
| Input Impedance | 68 KΩ, 2W |
| Relay Output | |
|---|---|
| Channels | 1 |
| Type | Power Relay, Form C (SPDT N.O+N.C..) |
| Contact Rating | 30 A @ 250 VAC |
| AC Load Current Measurement | Yes, 0 ~ 5 A range with 3% of FSR Accuracy. |
| Operate Time | 15 ms Max |
| Release Time | 22 ms Max. |
| Electrical Endurance | 100,000 ops. |
| Mechanical Endurance | 10,000,000 ops |
| Power on Value | Yes |
| Safe Value | Yes |
| Application Specification |
(1).Incandescent Lamp: 40W/ 220VAC * 5 Sets (2).LED(Electronic ballast): 40W/ 220VAC *8 Sets |
| Ethernet | |
|---|---|
| Node Address | 32 to 63 for hardware configuration |
| COM Ports | |
|---|---|
| Ports | 1 x RS-485 |
| Baud Rate |
Hardware Configuration: Fixed 9600 bps Software Configuration: 1200 to 115200 bps |
| Data Format | N,8,1/O,8,1/E,8,1/N,8,2 |
| Protocol | Modbus RTU/DCON |
| Power | |
|---|---|
| Reverse Polarity Protection | Yes |
| Input Range | 10 ~ 30 VDC |
| Consumption | 1.9 W Max. |
| Mechanical | |
|---|---|
| Dimensions (mm) | 72 mm x 95 mm x 57 mm |
| Installation | DIN-Rail |
| Environment | |
|---|---|
| Operating Temperature | -25 ~ +75°C |
| Storage Temperature | -30 ~ +75°C |
| Humidity | 10 ~ 95% RH, Non-condensing |