The M-7000 series is a family of network data acquisition and control modules that support Modbus RTU and DCON protocols. With the Modbus RTU protocol, the modules can easily communicate with most popular SCADA/ HMI software packages and PLC's. It has the same form factor as the I-7000 series.
The M-7080 offers 2 input channels which can act as 32-bit counters or be used for monitoring frequencies up to 100kHz. Two Digital Outputs are also included.
(I-7080B(D), M-7080B(D))
Counter Input |
|
Channels |
2 independent 32-bit counters, counter 0&1 |
Input Type |
Isolated or non-isolated |
Input Level for Isolation and Non-isolation |
Logic level 0:+1V max. |
Logic level 1: +3.5 to 30V |
|
Isolation Voltage |
3750Vrms |
Non-Isolated Input Threshold Voltage Level (Programmable) |
Logic level 0: 0 to +5V (default= 0.8V) |
Logic level 1: 0 to +5V (default= 2.4V) |
|
Maximum Count |
32bit (4,294,967,295) |
Programmable Digital Noise Filter |
2us to 65ms |
Alarming |
alarm on counter 0 or counter 0 & 1, programmable |
Counter Preset Value |
programmable |
Frequency Measurement |
|
Input Frequency |
1Hz to 100KHz max. |
Gate Time |
1.0 or 0.1sec, programmable |
Digital Output |
|
Channels |
2 |
Output Type |
Sink, Open-Collector |
Output Voltage |
30V max. |
Output Current |
30mA max |
Interface |
|
Interface |
RS-485 |
Format |
N, 8, 1 (details) |
Baud Rate |
1200 ~ 115200bps |
LED Display |
|
1 LED as Power/ Communication indicator |
|
5-digit readout, Channel 0 or Channel 1 (for M-7080D) |
|
Power |
|
Input Voltage Range |
10~30VDC |
Power Consumption |
2.0W (max.)(M-7080) / 2.2W (max.)(M-7080D) |
Protocol |
|
Support Modbus and DCON Protocol |
Yes |
Environment |
|
Operating Temperature |
-25 to 75°C |
Storage Temperature |
-40 to 85°C |
Humidity |
5 to 95%, non-condensing |
The M-7000 series is a family of network data acquisition and control modules that support Modbus RTU and DCON protocols. With the Modbus RTU protocol, the modules can easily communicate with most popular SCADA/ HMI software packages and PLC's. It has the same form factor as the I-7000 series.
The M-7080 offers 2 input channels which can act as 32-bit counters or be used for monitoring frequencies up to 100kHz. Two Digital Outputs are also included.
Counter Input |
|
Channels |
2 independent 32-bit counters, counter 0&1 |
Input Type |
Isolated or non-isolated |
Input Level for Isolation and Non-isolation |
Logic level 0:+1V max. |
Logic level 1: +3.5 to 30V |
|
Isolation Voltage |
3750Vrms |
Non-Isolated Input Threshold Voltage Level (Programmable) |
Logic level 0: 0 to +5V (default= 0.8V) |
Logic level 1: 0 to +5V (default= 2.4V) |
|
Maximum Count |
32bit (4,294,967,295) |
Programmable Digital Noise Filter |
2us to 65ms |
Alarming |
alarm on counter 0 or counter 0 & 1, programmable |
Counter Preset Value |
programmable |
Frequency Measurement |
|
Input Frequency |
1Hz to 100KHz max. |
Gate Time |
1.0 or 0.1sec, programmable |
Digital Output |
|
Channels |
2 |
Output Type |
Sink, Open-Collector |
Output Voltage |
30V max. |
Output Current |
30mA max |
Interface |
|
Interface |
RS-485 |
Format |
N, 8, 1 (details) |
Baud Rate |
1200 ~ 115200bps |
LED Display |
|
1 LED as Power/ Communication indicator |
|
5-digit readout, Channel 0 or Channel 1 (for M-7080D) |
|
Power |
|
Input Voltage Range |
10~30VDC |
Power Consumption |
2.0W (max.)(M-7080) / 2.2W (max.)(M-7080D) |
Protocol |
|
Support Modbus and DCON Protocol |
Yes |
Environment |
|
Operating Temperature |
-25 to 75°C |
Storage Temperature |
-40 to 85°C |
Humidity |
5 to 95%, non-condensing |