The iSN-301 is a Time-of-Flight sensing module that is designed specifically for non-contact distance measurement. It can measure distance up to 4 meters. The module can be configured to trigger LED alarm when the distance is too short or too long. It is possible to program the size and position of the ROI to adjust the sensor FoV. The module can be easily integrated with the host controller connected in the same RS-485 network via DCON or Modbus RTU protocol.
EMS Protection | |
---|---|
EFT (IEC 61000-4-4) | ±4 kV for Power |
ESD (IEC 61000-4-2) | ±8 kV Air for Random Point |
LED Indicators | |
---|---|
Status | 1 as Power Indicator. 1 as Alarm Indicator. |
Distance Measurement | |
---|---|
Detection Range | 5 cm ~ 4 m |
Detection Field of View | 15°; Diameter 0.8 meters Max. |
Accuracy | ±5% (±20 cm) |
Resolution | 1 mm |
Update Time | 20 ~5000 ms, programmable |
Sensor Direction | Horizontal |
Relay Output | |
---|---|
Type |
Signal Relay, Form A x1, SPST 0.25 A @ 250 VAC 0.5 A @ 125 VAC 2 A @ 30 VDC |
COM Ports | |
---|---|
Ports | 1 x RS-485 |
Baud Rate | Software Configurable: 1200 ~ 115200 bps |
Data Format | N,8,1 / O,8,1 / E,8,1 / N,8,2 |
Protocol | Modbus RTU or DCON |
Node Address |
0 ~ 255 for software configuration 96 ~ 127 for hardware configuration |
Power | |
---|---|
Reverse Polarity Protection | Yes |
Input Range | 10 ~ 30 VDC |
Consumption | 1.2 W Max. |
Mechanical | |
---|---|
Dimensions (mm) | 70 x 78 x 24 (W x L x H) |
Installation | Wall Mounting |
Environment | |
---|---|
Operating Temperature | -25 ~ +75°C |
Storage Temperature | -40 ~ +80°C |
Humidity | 10 ~ 90% RH, Non-condensing |
The iSN-301 is a Time-of-Flight sensing module that is designed specifically for non-contact distance measurement. It can measure distance up to 4 meters. The module can be configured to trigger LED alarm when the distance is too short or too long. It is possible to program the size and position of the ROI to adjust the sensor FoV. The module can be easily integrated with the host controller connected in the same RS-485 network via DCON or Modbus RTU protocol.
EMS Protection | |
---|---|
EFT (IEC 61000-4-4) | ±4 kV for Power |
ESD (IEC 61000-4-2) | ±8 kV Air for Random Point |
LED Indicators | |
---|---|
Status | 1 as Power Indicator. 1 as Alarm Indicator. |
Distance Measurement | |
---|---|
Detection Range | 5 cm ~ 4 m |
Detection Field of View | 15°; Diameter 0.8 meters Max. |
Accuracy | ±5% (±20 cm) |
Resolution | 1 mm |
Update Time | 20 ~5000 ms, programmable |
Sensor Direction | Horizontal |
Relay Output | |
---|---|
Type |
Signal Relay, Form A x1, SPST 0.25 A @ 250 VAC 0.5 A @ 125 VAC 2 A @ 30 VDC |
COM Ports | |
---|---|
Ports | 1 x RS-485 |
Baud Rate | Software Configurable: 1200 ~ 115200 bps |
Data Format | N,8,1 / O,8,1 / E,8,1 / N,8,2 |
Protocol | Modbus RTU or DCON |
Node Address |
0 ~ 255 for software configuration 96 ~ 127 for hardware configuration |
Power | |
---|---|
Reverse Polarity Protection | Yes |
Input Range | 10 ~ 30 VDC |
Consumption | 1.2 W Max. |
Mechanical | |
---|---|
Dimensions (mm) | 70 x 78 x 24 (W x L x H) |
Installation | Wall Mounting |
Environment | |
---|---|
Operating Temperature | -25 ~ +75°C |
Storage Temperature | -40 ~ +80°C |
Humidity | 10 ~ 90% RH, Non-condensing |