100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

CL-229-E PM,CO,CO2,HCHO,TVOC,Temperature,Humidity,Dew Point Data Logger (Enet)

CL-229-E  PM,CO,CO2,HCHO,TVOC,Temperature,Humidity,Dew Point Data Logger (Enet)
£78700

(£944.40 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:CL-229-E

Description

The CL-220 series of data logger devices can be used to record PM1/PM2.5/PM10 and the number of particles (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm), CO, CO2, NH3 , H2S, HCHO, TVOC, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.
 
Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iOS App, or the Android App, as long as they are connected to the same local network as the data logger.
 
Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.

 

Supports the MQTT Protocol for IoT Applications


Multi-platform Remote Access Software

Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.


 


Simple and Powerful iAir Utility 

The iAir Utility is a powerful tool that is designed for configuring the modules, monitoring real-time data, grouping CL-200 modules to view and manage the status of distribution groups, downloading log data, which can be exported to a CSV file that can then be imported into any industry-standard software or spreadsheet for analysis.

Features

  • Able to record PM1/PM2.5/PM10, CO, CO2, HCHO, TVOC, Temperature, Humidity and Dew Point
  • Non-dispersive Infrared (NDIR) CO2 Sensor
  • Up to 450,000 records with date and time stamps
  • Web-based Configuration Interface
  • Simple and Powerful Software Utility, iOS App and Android App Included
  • Supports the DCON, Modbus RTU/TCP, and MQTT Protocols
  • Features RS-485/Ethernet/PoE Communication Interfaces
  • Relay Output for Alarm or IAQ Device Control

Specifications

System
Alarm PM1/PM2.5/PM10/CO/CO2/HCHO/TVOC/RH/Temperature
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Temperature Measurement
Range -10 ~ +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Life Time 10 years
Humidity Measurement
Range 0 ~ 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
Life Time 10 years
Dew Point
Range Calculated using temperature and relative humidity
Resolution 0.1°C
CO Measurement
Range 0 to 1000 ppm (Electrochemical)
Resolution 1 ppm
Accuracy ±5% of measured value
Response Time 30 seconds
Warm-up Time 5 minutes
Life Time 5 years
CO2 Measurement
Range 0 to 9999 ppm (NDIR)
Resolution 1 ppm
Accuracy ±40 ppm ±3% of measured value
Response Time 120 seconds
Warm-up Time 5 minutes
Life Time 15 years
HCHO Measurement
Range 0 to 2000 ppb (Electrochemical)
Resolution 1 ppb
Accuracy -
Response Time ≤ 60 seconds
Warm-up Time 180 seconds
Life Time 3 years
TVOC Measurement
Range 0 ppb to 60000 ppb (MEMS Metal Oxide)
Resolution 1 ppb
Accuracy ±15%
Response Time 60 seconds
Warm-up Time 180 seconds
Life Time 5 years
PM1/PM2.5/PM10 Measurement
Range 0 to 1,000μg/m3 ( Laser Type)
Resolution 1μg/m3
Accuracy ± 10% of FSR.
Response Time 1 seconds
Warm-up Time 20 seconds
Life Time 5 years, Customer has to replace the filter patch.
Particle
Sizes 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Relay Output
Channels 1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports 1 x RS-485
1 x Ethernet
Protocol DCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Power
Consumption Non-PoE: 3.3 W (Max.)
PoE: 3.1 W (Max.)
Powered from Terminal Block +12 ~ +48 VDC
Mechanical
Dimensions (mm) Ø 150 x 53 (Ø x H)
Installation Ceiling Mounting/Wall Mounting
Ingress Protection Rating IP20
Environment
Operating Temperature 0 ~ 50°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

CL-229E Air Quality sensor and data logger datasheet  (not all CL-220 series variants are currently available)

Applications

  • Transportation of Food or Pharmaceuticals
  • Food and Beverage Industry (HACCP)
  • Blood Stations and Pharmacies
  • Building and Energy Management
  • Warehouse Management
  • Museums, Archives and Galleries

 

Indoor or Underground Parking Lot Automatic Monitoring Solution

The air quality automation system for indoor or underground parking lot can use the CL-220 series modules to monitor the health and safity information, such as PM1,PM2.5,PM10, CO, CO2, temperature, humidity, dew point, and more...
 

Description

The CL-220 series of data logger devices can be used to record PM1/PM2.5/PM10 and the number of particles (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm), CO, CO2, NH3 , H2S, HCHO, TVOC, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.
 
Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iOS App, or the Android App, as long as they are connected to the same local network as the data logger.
 
Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.

 

Supports the MQTT Protocol for IoT Applications


Multi-platform Remote Access Software

Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.


 


Simple and Powerful iAir Utility 

The iAir Utility is a powerful tool that is designed for configuring the modules, monitoring real-time data, grouping CL-200 modules to view and manage the status of distribution groups, downloading log data, which can be exported to a CSV file that can then be imported into any industry-standard software or spreadsheet for analysis.

Features

Specifications

System
Alarm PM1/PM2.5/PM10/CO/CO2/HCHO/TVOC/RH/Temperature
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Temperature Measurement
Range -10 ~ +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Life Time 10 years
Humidity Measurement
Range 0 ~ 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
Life Time 10 years
Dew Point
Range Calculated using temperature and relative humidity
Resolution 0.1°C
CO Measurement
Range 0 to 1000 ppm (Electrochemical)
Resolution 1 ppm
Accuracy ±5% of measured value
Response Time 30 seconds
Warm-up Time 5 minutes
Life Time 5 years
CO2 Measurement
Range 0 to 9999 ppm (NDIR)
Resolution 1 ppm
Accuracy ±40 ppm ±3% of measured value
Response Time 120 seconds
Warm-up Time 5 minutes
Life Time 15 years
HCHO Measurement
Range 0 to 2000 ppb (Electrochemical)
Resolution 1 ppb
Accuracy -
Response Time ≤ 60 seconds
Warm-up Time 180 seconds
Life Time 3 years
TVOC Measurement
Range 0 ppb to 60000 ppb (MEMS Metal Oxide)
Resolution 1 ppb
Accuracy ±15%
Response Time 60 seconds
Warm-up Time 180 seconds
Life Time 5 years
PM1/PM2.5/PM10 Measurement
Range 0 to 1,000μg/m3 ( Laser Type)
Resolution 1μg/m3
Accuracy ± 10% of FSR.
Response Time 1 seconds
Warm-up Time 20 seconds
Life Time 5 years, Customer has to replace the filter patch.
Particle
Sizes 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Relay Output
Channels 1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports 1 x RS-485
1 x Ethernet
Protocol DCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Power
Consumption Non-PoE: 3.3 W (Max.)
PoE: 3.1 W (Max.)
Powered from Terminal Block +12 ~ +48 VDC
Mechanical
Dimensions (mm) Ø 150 x 53 (Ø x H)
Installation Ceiling Mounting/Wall Mounting
Ingress Protection Rating IP20
Environment
Operating Temperature 0 ~ 50°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

CL-229E Air Quality sensor and data logger datasheet  (not all CL-220 series variants are currently available)

Applications

 

Indoor or Underground Parking Lot Automatic Monitoring Solution

The air quality automation system for indoor or underground parking lot can use the CL-220 series modules to monitor the health and safity information, such as PM1,PM2.5,PM10, CO, CO2, temperature, humidity, dew point, and more...
 