Description

WISE (Web Inside, Smart Engine) is a product series that function as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers with just a few clicks; no programming is required. With the built-in IF-THEN-ELSE logic engine, WISE can execute the automation logic in a stable and efficient way, and it also provides mathematic operation, Schedule and Email alarm message sending functions.

WISE-5231 provides more supports in I/O module connection, I/O data logging and IoT platform integration. It allows connection to XV-board, DCON I/O modules, and Modbus TCP/RTU Slave modules all together. The wide range of selection options enables flexibility in I/O module integration to meet the requirements from various applications.

WISE-5231 includes an MQTT client, which allows it to directly connect to the major public IoT Cloud platforms (such as: Microsoft Azure or IBM Bluemix) and MQTT Broker.

The WISE unit also provides well thought-out CGI command functions to integrate with IP cameras for the Access Control applications. Based on the ability as I/O module connection ability, Intelligent logic control, Data logging, and various communication protocols supported (SNMP, MQTT and Modbus TCP/RTU), WISE can help the IT/MIS/MES/SCADA system to manage the field side I/O modules and sensors efficiently in the application such as Unmanned Facility Room Monitoring, Intelligent Factory and Environment Monitoring. WISE-5231 is not just a Concentrator of I/O modules and Sensors; it is also a Gateway to transfer the sensor data to IoT Cloud platform.

All of these make WISE-5231 the best choice in the IoT Age.

Features

  • Runs on browsers, no extra software tool is required
  • No more programming, Web pages provided for control logic editing
  • IF-THEN-ELSE logic rules execution ability
  • Support XV-board
  • Support DCON or Modbus RTU Slave devices (Up to 32)
  • Support Modbus TCP Slave devices (Up to 16)
  • SSL/TLS Email sending function supported
  • Timer and Schedule functions supported
  • Data logger and data files send back function supported
  • Active I/O sending function for real-time data transfer
  • CGI Command sending and receiving function supported for IP Camera and Network device
  • Support Modbus TCP/RTU, SNMP, FTP and MQTT protocols
  • Support Connection with IoT Cloud Platform (Microsoft Azure and IBM Bluemix)

Specifications

Hardware Specifications

System
CPU 32-bit ARM CPU
Software Built-in WISE Firmware
microSD Expansion Built-in one 4 GB microSD card (support up to 32 GB microSDHC card)
RTC (Real Time Clock) Yes
VGA Yes
Communication
Ethernet RJ-45 x 1, 10/100/1000 Base-TX (Auto-negotiating, Auto MDI/MDI-X)
COM 1 RS-232 (TxD, RxD, GND), non-isolated, Speed: 115200 bps max
COM 2 RS-232 (TxD, RxD, GND), non-isolated, Speed: 115200 bps max.
COM 3 RS-485 (Data+, Data-), non-isolated, Speed: 115200 bps max.
COM 4 RS-485 (Data+, Data-), 2500 VDC isolated, Speed: 115200 bps max.
LED Indicators
Power LED Yes (Red)
System LED Yes (Red, Green)
I/O Module Support
Local I/O Module Yes, one XV-board
Remote I/O Module DCON modules (up to 32) or Modbus RTU Slave modules (up to 32),
Modbus TCP Slave modules (up to 16)
Power Requirements
Input Range 12 to 48 VDC
Power Consumption 4.8 W
Mechanical
Dimensions/Installation 91 mm x 132 mm x 52 mm (W x L x H) / DIN-Rail Installation
Environmental
Temperature Operating Temperature: -25 °C to +75 °C; Storage Temperature: -40 °C to +80 °C
Humidity 10 to 90% RH, Non-condensing

Software Specifications

Functions
Web Operation Interface Access built-in webpage interface on WISE controllers to set up system parameters, edit logic rules and perform I/O channel status monitoring through web browser.
IF-THEN-ELSE Rule Provide Web UI interface for the IF-THEN-ELSE logic rule editing, and the ability for IF-THEN-ELSE logic rules execution.
Timer Perform the timing function. The status of Timer can be included in IF condition statements to trigger the THEN/ELSE actions.
Schedule Perform the prescheduled routine tasks. The status of Schedule can be included in IF condition statements to trigger the THEN/ELSE actions. “Calendar” and “Weekly repeat” schedule setting UI are provided.
Email Execute Email message sending. The SSL authentication is provided.
CGI Command Perform CGI command sending and CGI command receiving functions. The content of CGI command receiving can be used in IF condition statements to trigger the THEN/ELSE actions.
Data Logger Enable WISE to record I/O channel data in Data Log file. The Data Log files can be sent to the FTP server for users, or user can actively download them from the FTP client utility or Web page.
Recording rates from every 5 secs to every hour.
Internal Register Work as a variable to hold the temporary value, and provide the basic mathematical operation. SCADA software can Read/write the value via Modbus TCP/RTU Protocol remotely.
Active I/O Sending Actively send I/O channel data to the receivers (require Modbus TCP Slave function).
Modbus TCP/RTU Protocol Perform real time control and monitoring of I/O channels and system status via SCADA software or HMI devices.
SNMP Support SNMP V2c protocol, and provide the IF-THEN-ELSE rule setting to trigger the SNMP Trap sending.
MQTT Work with MQTT Broker for the message publish/subscribe mechanism.

 

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

Description

WISE (Web Inside, Smart Engine) is a product series that function as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers with just a few clicks; no programming is required. With the built-in IF-THEN-ELSE logic engine, WISE can execute the automation logic in a stable and efficient way, and it also provides mathematic operation, Schedule and Email alarm message sending functions.

WISE-5231 provides more supports in I/O module connection, I/O data logging and IoT platform integration. It allows connection to XV-board, DCON I/O modules, and Modbus TCP/RTU Slave modules all together. The wide range of selection options enables flexibility in I/O module integration to meet the requirements from various applications.

WISE-5231 includes an MQTT client, which allows it to directly connect to the major public IoT Cloud platforms (such as: Microsoft Azure or IBM Bluemix) and MQTT Broker.

The WISE unit also provides well thought-out CGI command functions to integrate with IP cameras for the Access Control applications. Based on the ability as I/O module connection ability, Intelligent logic control, Data logging, and various communication protocols supported (SNMP, MQTT and Modbus TCP/RTU), WISE can help the IT/MIS/MES/SCADA system to manage the field side I/O modules and sensors efficiently in the application such as Unmanned Facility Room Monitoring, Intelligent Factory and Environment Monitoring. WISE-5231 is not just a Concentrator of I/O modules and Sensors; it is also a Gateway to transfer the sensor data to IoT Cloud platform.

All of these make WISE-5231 the best choice in the IoT Age.

Features

Specifications

Hardware Specifications

System
CPU 32-bit ARM CPU
Software Built-in WISE Firmware
microSD Expansion Built-in one 4 GB microSD card (support up to 32 GB microSDHC card)
RTC (Real Time Clock) Yes
VGA Yes
Communication
Ethernet RJ-45 x 1, 10/100/1000 Base-TX (Auto-negotiating, Auto MDI/MDI-X)
COM 1 RS-232 (TxD, RxD, GND), non-isolated, Speed: 115200 bps max
COM 2 RS-232 (TxD, RxD, GND), non-isolated, Speed: 115200 bps max.
COM 3 RS-485 (Data+, Data-), non-isolated, Speed: 115200 bps max.
COM 4 RS-485 (Data+, Data-), 2500 VDC isolated, Speed: 115200 bps max.
LED Indicators
Power LED Yes (Red)
System LED Yes (Red, Green)
I/O Module Support
Local I/O Module Yes, one XV-board
Remote I/O Module DCON modules (up to 32) or Modbus RTU Slave modules (up to 32),
Modbus TCP Slave modules (up to 16)
Power Requirements
Input Range 12 to 48 VDC
Power Consumption 4.8 W
Mechanical
Dimensions/Installation 91 mm x 132 mm x 52 mm (W x L x H) / DIN-Rail Installation
Environmental
Temperature Operating Temperature: -25 °C to +75 °C; Storage Temperature: -40 °C to +80 °C
Humidity 10 to 90% RH, Non-condensing

Software Specifications

Functions
Web Operation Interface Access built-in webpage interface on WISE controllers to set up system parameters, edit logic rules and perform I/O channel status monitoring through web browser.
IF-THEN-ELSE Rule Provide Web UI interface for the IF-THEN-ELSE logic rule editing, and the ability for IF-THEN-ELSE logic rules execution.
Timer Perform the timing function. The status of Timer can be included in IF condition statements to trigger the THEN/ELSE actions.
Schedule Perform the prescheduled routine tasks. The status of Schedule can be included in IF condition statements to trigger the THEN/ELSE actions. “Calendar” and “Weekly repeat” schedule setting UI are provided.
Email Execute Email message sending. The SSL authentication is provided.
CGI Command Perform CGI command sending and CGI command receiving functions. The content of CGI command receiving can be used in IF condition statements to trigger the THEN/ELSE actions.
Data Logger Enable WISE to record I/O channel data in Data Log file. The Data Log files can be sent to the FTP server for users, or user can actively download them from the FTP client utility or Web page.
Recording rates from every 5 secs to every hour.
Internal Register Work as a variable to hold the temporary value, and provide the basic mathematical operation. SCADA software can Read/write the value via Modbus TCP/RTU Protocol remotely.
Active I/O Sending Actively send I/O channel data to the receivers (require Modbus TCP Slave function).
Modbus TCP/RTU Protocol Perform real time control and monitoring of I/O channels and system status via SCADA software or HMI devices.
SNMP Support SNMP V2c protocol, and provide the IF-THEN-ELSE rule setting to trigger the SNMP Trap sending.
MQTT Work with MQTT Broker for the message publish/subscribe mechanism.

 

Technical

WISE-5231 Datasheet

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.