The I-7022 is a 12-bit, 2-channel analog output module with an RS485 interface, using the DCON Protocol. It can offer either current output or voltage output, with the power source for the current output can be selected as either internal or external via a jumper. There are options for power on value and safe value, while the I-7022 also features 3000 VDC intra-module isolation.
A wide range of software drivers are available, including a driver for our own Orchestrator package. Please call us for more information.
I/O Specifications
Models | I-7022 | M-7022 | M-7022A | |
Analog Output | ||||
Channels | 2 | |||
Range | Voltage | 0 ~ +5 V, 0 ~ +10 V, | 0 ~ +5 V, 0 ~ +10 V, ±5 V, ±10 V | |
Current | 0 ~ +20 mA, +4 ~ +20 mA | |||
Resolution | 12-bit | |||
Accuracy | 0.1% | |||
Readback Accuracy | ±0.5% of FSR | |||
DA Output Response Time | 10 ms | |||
Programmable Output Slope | Voltage | 0.0625 ~ 1024.0 V/Second | ||
Current | 0.125 ~ 2048 mA/Second | |||
Current Load Resistance | Internal Power: 500 Ω | |||
External Power: 1050 Ω | ||||
Open Wire Detection (for current only) | Yes | |||
Channel-to-Channel Isolation | Yes, 2 kV | |||
Short Circuit Protection | Yes | |||
Power-on Value | Yes | |||
Safe Value | Yes |
System Specifications
Models | I-7022 | M-7022 | M-7022A |
Communication | |||
Interface | RS-485 | ||
RS-485 Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) | ||
Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) | ||
Baud Rate | 1200 to 115200 bps | ||
Protocol | DCON | Modbus RTU, DCON | |
Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | ||
LED Indicator/Display | |||
System LED Indicator | Yes, 1 as Power/Communication Indicator | ||
I/O LED Indicator | - | ||
7-Segment LED Display | - | ||
Isolation | |||
Intra-Module Isolation, Field-to-Logic | 3000 VDC | ||
EMS Protection | |||
ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | ||
EFT (IEC 61000-4-4) | ±4 kV to Power Line | ||
Surge (IEC 61000-4-5) | ±0.5 kV for Power Line | ||
Power | |||
Reverse Polarity Protection | Yes | ||
Input Range | +10 ~ +30 VDC | ||
Consumption | 3.0 W | ||
Mechanical | |||
Dimensions (L x W x H) | 123 mm x 72 mm x 35 mm | ||
Installation | DIN-Rail or Wall Mounting | ||
Environment | |||
Operating Temperature | -25 to +75°C | ||
Storage Temperature | -40 to +85°C | ||
Humidity | 10 to 95% RH, Non-condensing |
The I-7022 is a 12-bit, 2-channel analog output module with an RS485 interface, using the DCON Protocol. It can offer either current output or voltage output, with the power source for the current output can be selected as either internal or external via a jumper. There are options for power on value and safe value, while the I-7022 also features 3000 VDC intra-module isolation.
A wide range of software drivers are available, including a driver for our own Orchestrator package. Please call us for more information.
I/O Specifications
Models | I-7022 | M-7022 | M-7022A | |
Analog Output | ||||
Channels | 2 | |||
Range | Voltage | 0 ~ +5 V, 0 ~ +10 V, | 0 ~ +5 V, 0 ~ +10 V, ±5 V, ±10 V | |
Current | 0 ~ +20 mA, +4 ~ +20 mA | |||
Resolution | 12-bit | |||
Accuracy | 0.1% | |||
Readback Accuracy | ±0.5% of FSR | |||
DA Output Response Time | 10 ms | |||
Programmable Output Slope | Voltage | 0.0625 ~ 1024.0 V/Second | ||
Current | 0.125 ~ 2048 mA/Second | |||
Current Load Resistance | Internal Power: 500 Ω | |||
External Power: 1050 Ω | ||||
Open Wire Detection (for current only) | Yes | |||
Channel-to-Channel Isolation | Yes, 2 kV | |||
Short Circuit Protection | Yes | |||
Power-on Value | Yes | |||
Safe Value | Yes |
System Specifications
Models | I-7022 | M-7022 | M-7022A |
Communication | |||
Interface | RS-485 | ||
RS-485 Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) | ||
Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) | ||
Baud Rate | 1200 to 115200 bps | ||
Protocol | DCON | Modbus RTU, DCON | |
Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | ||
LED Indicator/Display | |||
System LED Indicator | Yes, 1 as Power/Communication Indicator | ||
I/O LED Indicator | - | ||
7-Segment LED Display | - | ||
Isolation | |||
Intra-Module Isolation, Field-to-Logic | 3000 VDC | ||
EMS Protection | |||
ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | ||
EFT (IEC 61000-4-4) | ±4 kV to Power Line | ||
Surge (IEC 61000-4-5) | ±0.5 kV for Power Line | ||
Power | |||
Reverse Polarity Protection | Yes | ||
Input Range | +10 ~ +30 VDC | ||
Consumption | 3.0 W | ||
Mechanical | |||
Dimensions (L x W x H) | 123 mm x 72 mm x 35 mm | ||
Installation | DIN-Rail or Wall Mounting | ||
Environment | |||
Operating Temperature | -25 to +75°C | ||
Storage Temperature | -40 to +85°C | ||
Humidity | 10 to 95% RH, Non-condensing |