Temperature Measurement | |
---|---|
Range | -25 ~ +75°C (-13 ~ +167°F) |
Resolution | 0.1°C |
Accuracy | Typical: ±0.4°C |
Precision | ±0.1°C |
Humidity Measurement | |
---|---|
Range | 0 ~ 95% RH |
Resolution | 0.1°C |
Accuracy | Typical: ±3% RH @ 20 ~ 80% RH |
Precision | ±0.1°C |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
Atmospheric Pressure | |
---|---|
Range | 300 ~ 1200 hPa |
Accuracy | 1 hPa |
Resolution | 0.1 hPa |
COM Ports | |
---|---|
Ports | 1 x RS-485, Non-isolated |
Baud Rate | 1200 ~ 115200 bps |
Data Format | (N, 8, 1) |
Protocol | Modbus RTU |
Power | |
---|---|
Input Range | +10 ~ +30 VDC |
Consumption | 0.05 W |
Mechanical | |
---|---|
Dimensions (mm) | 25 x 20.2 x 30 (W x L x H) |
Installation |
Magnetic mount; Wall mount |
Cable Length | 3 m |
Environment | |
---|---|
Operating Temperature | -25 ~ +75°C |
Storage Temperature | -30 ~ +80°C |
Humidity | 0 ~ 95% RH, Non-condensing |
The DL-11 is able to provide real-time temperature, humidity, atmospheric pressure and dew point information by RS-485 with Modbus RTU protocol.
DCON Utility Pro provides easy and convenient interface for users to configure the module. Based on its amazing tiny size, the DL-11 achieves the goal of space-saving that allows it to be installed anywhere.
Temperature Measurement | |
---|---|
Range | -25 ~ +75°C (-13 ~ +167°F) |
Resolution | 0.1°C |
Accuracy | Typical: ±0.4°C |
Precision | ±0.1°C |
Humidity Measurement | |
---|---|
Range | 0 ~ 95% RH |
Resolution | 0.1°C |
Accuracy | Typical: ±3% RH @ 20 ~ 80% RH |
Precision | ±0.1°C |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
Atmospheric Pressure | |
---|---|
Range | 300 ~ 1200 hPa |
Accuracy | 1 hPa |
Resolution | 0.1 hPa |
COM Ports | |
---|---|
Ports | 1 x RS-485, Non-isolated |
Baud Rate | 1200 ~ 115200 bps |
Data Format | (N, 8, 1) |
Protocol | Modbus RTU |
Power | |
---|---|
Input Range | +10 ~ +30 VDC |
Consumption | 0.05 W |
Mechanical | |
---|---|
Dimensions (mm) | 25 x 20.2 x 30 (W x L x H) |
Installation |
Magnetic mount; Wall mount |
Cable Length | 3 m |
Environment | |
---|---|
Operating Temperature | -25 ~ +75°C |
Storage Temperature | -30 ~ +80°C |