(£237.60 incl VAT)
FREE delivery to UK on orders over £500
100% Money Back
30 Day Guarantee
International Shipping
Over 100 Countries
The I-2533 is a local CAN bridge used to establish a connection between two CAN bus system via a fibre-optic connection. The I-2533 is especially designed for converting the electrical CAN bus signal to fiber optic cables and has three additional features over the standard I-2532 CAN-Fibre converter.
Note: ICP have verified to drive 100 CAN nodes at the same time via one CAN port of I-2533.
CAN Interface
|
|
Connector
|
Screwed terminal block (CAN_GND, CAN_L, CAN_H)
|
Baud Rate (bps)
|
10 k ~ 1 M
|
Transmission Distance (m)
|
Depend on baud rate
|
Terminator Resistor
|
Switch for 120Ω terminator resistor
|
Isolation
|
3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
|
Specification
|
ISO-11898-2, CAN 2.0A and CAN 2.0B
|
Time Delay
|
120us max (CAN to fiber or fiber to CAN)
|
Fiber Interface
|
|
Connector
|
ST (Multi-mode)
|
Wave Length
|
850 nm
|
Fiber Cable
|
50 / 125 μm , 62.5 / 125 μm, 100 / 140 μm (62.5 / 125μm is recommended)
|
Transmission Distance (m)
|
2 km max (in 62.5 / 125 μm fiber cable) at any CAN baud rate
|
LED
|
|
Round LED
|
PWR LED, CAN_Tx LED, CAN_Rx LED, CAN_Err LED, FB_Err LED
|
Power
|
|
Power supply
|
Unregulated +10 ~ +30 VDC
|
Protection
|
Power reverse polarity protection, Over-voltage brown-out protection
|
Power Consumption
|
3 W
|
Mechanism
|
|
Installation
|
DIN-Rail
|
Dimensions
|
32.3mm x 77.5mm x 99.0mm (W x L x H)
|
Environment
|
|
Operating Temp.
|
-25 ~ 75 ?
|
Storage Temp.
|
-30 ~ 80 ?
|
Humidity
|
10 ~ 90% RH, non-condensing
|
The I-2533 is a local CAN bridge used to establish a connection between two CAN bus system via a fibre-optic connection. The I-2533 is especially designed for converting the electrical CAN bus signal to fiber optic cables and has three additional features over the standard I-2532 CAN-Fibre converter.
Note: ICP have verified to drive 100 CAN nodes at the same time via one CAN port of I-2533.
CAN Interface
|
|
Connector
|
Screwed terminal block (CAN_GND, CAN_L, CAN_H)
|
Baud Rate (bps)
|
10 k ~ 1 M
|
Transmission Distance (m)
|
Depend on baud rate
|
Terminator Resistor
|
Switch for 120Ω terminator resistor
|
Isolation
|
3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
|
Specification
|
ISO-11898-2, CAN 2.0A and CAN 2.0B
|
Time Delay
|
120us max (CAN to fiber or fiber to CAN)
|
Fiber Interface
|
|
Connector
|
ST (Multi-mode)
|
Wave Length
|
850 nm
|
Fiber Cable
|
50 / 125 μm , 62.5 / 125 μm, 100 / 140 μm (62.5 / 125μm is recommended)
|
Transmission Distance (m)
|
2 km max (in 62.5 / 125 μm fiber cable) at any CAN baud rate
|
LED
|
|
Round LED
|
PWR LED, CAN_Tx LED, CAN_Rx LED, CAN_Err LED, FB_Err LED
|
Power
|
|
Power supply
|
Unregulated +10 ~ +30 VDC
|
Protection
|
Power reverse polarity protection, Over-voltage brown-out protection
|
Power Consumption
|
3 W
|
Mechanism
|
|
Installation
|
DIN-Rail
|
Dimensions
|
32.3mm x 77.5mm x 99.0mm (W x L x H)
|
Environment
|
|
Operating Temp.
|
-25 ~ 75 ?
|
Storage Temp.
|
-30 ~ 80 ?
|
Humidity
|