(£55.20 incl VAT)
FREE delivery to UK on orders over £500
100% Money Back
30 Day Guarantee
International Shipping
Over 100 Countries
DIN-rail mounting Power supply with a 24Vdc/2.5A (60W) rated output and a wide input range. Also includes a relay contact for DC okay indication.
| Input | |
| Voltage range |
85 ~ 264 VAC 120 ~ 370 VDC |
| Frequency range | 47 ~ 63 Hz |
| Efficiency (Typ.) | 88% |
| Leakage current (max.) |
1.8 A/115 VAC 1 A/230 VAC |
| Inrush Current (Typ.) |
COLD START 30 A/115 VAC 60 A/230 VAC |
| Leakage current | <1 mA / 240 VAC |
| Output | |
| DC Voltage | 24 V |
| Rated Current | 2.5 A |
| Current Range | 0 ~ 2.5 A |
| Rated power | 60 W |
| Ripple & noise (max.) Note.2 | 150mVp-p |
| Voltage ADJ. range | 24 ~ 30 V |
| Voltage Tolerance Note.3 | ±1.0% |
| Line Regulation | ±1.0% |
| Load regulation | ±1.0% |
| Setup, rise Time Note.5 |
500 ms, 30 ms/230 VAC 500 ms, 30 m/115 VAC at full load |
| Protection | |
| Overload | 105 ~ 160% rated output power |
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |
| Over voltage | 31.2 ~ 36V |
| Protection type : Shut down o/p voltage, re-power on to recover | |
| Function | |
| DC OK signal | Relay contact rating(max.): 30V/1A resistive |
| Environmental | |
| Working temp. | -20 ~ +70°C (Refer to output load derating curve) |
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage TEMP., humidity | -40 ~ +85°C , 10 ~ 95% RH |
| TEMP. Coefficient | ±0.03%/°C (0 ~ 50°C) |
| Vibration |
Component : each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. |
| Safety & EMC (Note 4) | |
| Safety standards | UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24V,48V only) |
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25°C 70%RH |
| EMI Conduction & Radiation | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B |
| Hsrmonic current | Compliance to EN61000-3-2,-3 |
| EMS immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
| DC OK Relay Contact | |
| Contact Close | When the output voltage reaches the adjusted output voltage. |
| Contact Open | When the output voltage drop below 90% output voltage. |
| Contact Ratings (max.) | 30V/1A resistive load |
| Others | |
| MTBF |
299.2K hrs min. MIL-HDBK-217F (25°C) |
| Dimension (W x H x D) | 40 mm x 90 mm x 100 mm |
| Packing | 0.33Kg; 42pcs/14.8Kg/0.82CUFT |
| NOTE | |
|
|

DIN-rail mounting Power supply with a 24Vdc/2.5A (60W) rated output and a wide input range. Also includes a relay contact for DC okay indication.
| Input | |
| Voltage range |
85 ~ 264 VAC 120 ~ 370 VDC |
| Frequency range | 47 ~ 63 Hz |
| Efficiency (Typ.) | 88% |
| Leakage current (max.) |
1.8 A/115 VAC 1 A/230 VAC |
| Inrush Current (Typ.) |
COLD START 30 A/115 VAC 60 A/230 VAC |
| Leakage current | <1 mA / 240 VAC |
| Output | |
| DC Voltage | 24 V |
| Rated Current | 2.5 A |
| Current Range | 0 ~ 2.5 A |
| Rated power | 60 W |
| Ripple & noise (max.) Note.2 | 150mVp-p |
| Voltage ADJ. range | 24 ~ 30 V |
| Voltage Tolerance Note.3 | ±1.0% |
| Line Regulation | ±1.0% |
| Load regulation | ±1.0% |
| Setup, rise Time Note.5 |
500 ms, 30 ms/230 VAC 500 ms, 30 m/115 VAC at full load |
| Protection | |
| Overload | 105 ~ 160% rated output power |
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |
| Over voltage | 31.2 ~ 36V |
| Protection type : Shut down o/p voltage, re-power on to recover | |
| Function | |
| DC OK signal | Relay contact rating(max.): 30V/1A resistive |
| Environmental | |
| Working temp. | -20 ~ +70°C (Refer to output load derating curve) |
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage TEMP., humidity | -40 ~ +85°C , 10 ~ 95% RH |
| TEMP. Coefficient | ±0.03%/°C (0 ~ 50°C) |
| Vibration |
Component : each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. |
| Safety & EMC (Note 4) | |
| Safety standards | UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24V,48V only) |
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25°C 70%RH |
| EMI Conduction & Radiation | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B |
| Hsrmonic current | Compliance to EN61000-3-2,-3 |
| EMS immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
| DC OK Relay Contact | |
| Contact Close | When the output voltage reaches the adjusted output voltage. |
| Contact Open | When the output voltage drop below 90% output voltage. |
| Contact Ratings (max.) | 30V/1A resistive load |
| Others | |
| MTBF |
299.2K hrs min. MIL-HDBK-217F (25°C) |
| Dimension (W x H x D) | 40 mm x 90 mm x 100 mm |
| Packing | 0.33Kg; 42pcs/14.8Kg/0.82CUFT |
| NOTE | |
|
|