GW-2493M BACnet/IP To Modbus TCP Gateway

GW-2493M BACnet/IP to Modbus TCP Gateway
£45400

(£544.80 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:GW-2493M

Description

GW-2493M is a network gateway allowing BACnet client devices to be accessed Modbus network as a Modbus TCP client.

The BACnet/IP protocol is used to relay and exchange information between building devices. GW-2493M contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus TCP registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B,…etc.) are supported. All the data transfer is configurable using a standard Web browser.

Features

  • Read/Write Modbus registers via BACnet objects
  • Configurable BACnet/IP Server
  • Configurable Modbus TCP Client
  • Supports BACnet AI, AO, AV, BI, BO, BV, MSI, MSO, MSV Object Types
  • Supports Modbus discrete inputs, coils, input registers and holding registers
  • Supports up to 180 DI, 180 DO, 180 AI and 180 AO to transfer to BACnet Objects
  • Simple data translation allows you to manipulate data as it passes between protocol

Specifications

LED Indicators
Status Power (1), BACnet/IP Status (1), BACnet/IP Net(1),
Modbus TCP TxD/RxD/Link (3)
Ethernet LED Ethernet Status (RJ-45) (2)
Ethernet
Ports 1 x RJ-45, 10/100Base-TX
BACnet/IP
Protocol Modbus TCP Client(Supports up to 32 stations)
Objects AI, AO, AV, BI, BO, BV, MSI, MSO, MSV(Convert modbus 600 DI, 600 DO, 600 AI and 600 AO)
BIBBs DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-B
Power
Input Range +10 ~ +30 VDC
Consumption 5 W @ 24 VDC
Mechanical
Casing Metal
Dimensions (mm) 33 x 120 x 116
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

 

Applications

  • Building Automation
  • Heating, Ventilating, and Air-conditioning Control
  • Lighting Control
  • Access Control
  • Fire Detection Systems

Description

GW-2493M is a network gateway allowing BACnet client devices to be accessed Modbus network as a Modbus TCP client.

The BACnet/IP protocol is used to relay and exchange information between building devices. GW-2493M contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus TCP registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B,…etc.) are supported. All the data transfer is configurable using a standard Web browser.

Features

Specifications

LED Indicators
Status Power (1), BACnet/IP Status (1), BACnet/IP Net(1),
Modbus TCP TxD/RxD/Link (3)
Ethernet LED Ethernet Status (RJ-45) (2)
Ethernet
Ports 1 x RJ-45, 10/100Base-TX
BACnet/IP
Protocol Modbus TCP Client(Supports up to 32 stations)
Objects AI, AO, AV, BI, BO, BV, MSI, MSO, MSV(Convert modbus 600 DI, 600 DO, 600 AI and 600 AO)
BIBBs DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-B
Power
Input Range +10 ~ +30 VDC
Consumption 5 W @ 24 VDC
Mechanical
Casing Metal
Dimensions (mm) 33 x 120 x 116
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

GW-2493 BACNet/IP to ModbusTCP converter datasheet

Applications