Description

The SC Series current switch monitors line current for electrical loads such as pumps, conveyors, lighting, heaters or fans and closes the output contacts when the trip point is exceeded.

 
The SC-610-200 has a trip point that is adjustable between 2 to 200 Amps by rotating the adjustment pot. A LED illuminates when trip point setting is reached.

The sensor requires no external power as it is totally powered by induction from the AC line being 
monitored. The switch output is normally open and when the input current exceeds the trip setpoint the switch closes to provide an on/o digital signal to the controller.
 
The SC-610-200 can be opened to install on an existing wire which eliminates the need to disconnect. 

Specifications

  • Current Setpoint: 2 to 200 Amps
  • Maximum Input Current: 200 Amps continuous
  • Sensor Power: Self-powered
  • Output Type: Solid-state mosfet
  • Output Switch Action: Normally open
  • Output Switch Ratings: 30 Vac/dc, 500 mA Max.
  • Indication: Power & Status LED 
  • Von @ 24 Vdc at 500mA: < 50 mV
  • Frequency: 50/60 Hz
  • Response Time: 200 mS Typical
  • Insulation Class: 600 Vac, insulated conductors
  • Operating Temperature: -15 to 50 °C  (5 to 122 °F)  
  • Operating Humidity: 5 to 90% RH non-condensing
  • Terminal Block: 14 to 22 AWG
  • Dimensions: 76 x 79 x 24.9 mm   (3 x 3.1 x 0.98 in)
  • Sensor Aperture: 20.34 mm (0.8 in)
  • Enclosure Material: ABS/PC, UL94 V-0
  • Agency Approvals: cULus Listed

 

Description

The SC Series current switch monitors line current for electrical loads such as pumps, conveyors, lighting, heaters or fans and closes the output contacts when the trip point is exceeded.

 
The SC-610-200 has a trip point that is adjustable between 2 to 200 Amps by rotating the adjustment pot. A LED illuminates when trip point setting is reached.

The sensor requires no external power as it is totally powered by induction from the AC line being 
monitored. The switch output is normally open and when the input current exceeds the trip setpoint the switch closes to provide an on/o digital signal to the controller.
 
The SC-610-200 can be opened to install on an existing wire which eliminates the need to disconnect. 

Specifications

  • Current Setpoint: 2 to 200 Amps
  • Maximum Input Current: 200 Amps continuous
  • Sensor Power: Self-powered
  • Output Type: Solid-state mosfet
  • Output Switch Action: Normally open
  • Output Switch Ratings: 30 Vac/dc, 500 mA Max.
  • Indication: Power & Status LED 
  • Von @ 24 Vdc at 500mA: < 50 mV
  • Frequency: 50/60 Hz
  • Response Time: 200 mS Typical
  • Insulation Class: 600 Vac, insulated conductors
  • Operating Temperature: -15 to 50 °C  (5 to 122 °F)  
  • Operating Humidity: 5 to 90% RH non-condensing
  • Terminal Block: 14 to 22 AWG
  • Dimensions: 76 x 79 x 24.9 mm   (3 x 3.1 x 0.98 in)
  • Sensor Aperture: 20.34 mm (0.8 in)
  • Enclosure Material: ABS/PC, UL94 V-0
  • Agency Approvals: cULus Listed

 