To give you the best experience we use cookies. Learn More

OK

100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

CL-208-E TVOC, Temp, RH, Dew Point Data Logger (Ethernet)

CL-208-E  TVOC, Temp, RH, Dew point Data Logger (Ethernet)
£20900

(£250.80 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:CL-208-E

Description

The CL-200 series of data logger devices can be used to record CO, CO2, HCHO, TVOC, NH3, H2S, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.

Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iSO App, or the Android App, as long as they are connected to the same local network as the data logger.

Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machineto-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems. 
    


Supports the MQTT Protocol for IoT Applications



Multi-platform Remote Access Software
Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger. 
 
  
 
Simple and Powerful CL-200-E Utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group CL-200-E modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.

Features

  • Able to record TVOC, Temperature, Humidity and Dew Point Measurements 
  • HCHO : Electrochemical Sensor 
  • VCO : Metal-Oxide Sensor 
  • Up to 450,000 records with date and time stamps 
  • Supports the DCON, Modbus RTU/TCP, and MQTT Protocols 
  • Includes RS-485/Ethernet Communication Interfaces 
  • Relay Output for Alarm or IAQ Device Control 

Specifications

Temperature Measurement
Range -10 ~ +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Humidity Measurement
Range 0 ~ 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
TVOC Measurement
Range 0 ppb to 60000 ppb (MEMS Metal Oxide)
Resolution 1 ppb
Accuracy ±15%
Response Time 60 seconds
Warm-up Time 180 seconds
System
Alarm TVOC/RH/Temperature
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Relay Output
Channels 1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
COM Ports
Ports 1 x RS-485
1 x Ethernet
Protocol DCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Ethernet
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
Power
Consumption Non-PoE: 1.9 W (Max.)
PoE: 2.0 W (Max.)
Powered from Terminal Block +12 ~ +48 VDC
Mechanical
Dimensions (mm) Ø 150 x 53 (Ø x H)
Installation Ceiling Mounting/Wall Mounting
Ingress Protection Rating IP20
Environmental
Operating Temperature 0 ~ 50°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing

 

Applications

  • Transportation of Food or Pharmaceuticals
  • Food and Beverage Industry (HACCP)
  • Blood Stations and Pharmacies
  • Building and Energy Management
  • Warehouse Management
  • Museums, Archives and Galleries

 

Indoor or Underground Parking Lot Automatic Monitoring Solution
The air quality automation system for indoor or underground parking lot can use the CL-200 series modules to monitor the health and safity information, such as CO, CO2, temperature, humiditym, dew point, and more...




HCHO (Formaldehyde) Detector Automatic Solution
The HCHO/VOC detector provides an instantaneously warning of toxic formaldehyde, which can be found in a plywood factory, furniture factory and new interior remodelling house commonly.

Description

The CL-200 series of data logger devices can be used to record CO, CO2, HCHO, TVOC, NH3, H2S, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.

Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iSO App, or the Android App, as long as they are connected to the same local network as the data logger.

Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machineto-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems. 
    


Supports the MQTT Protocol for IoT Applications



Multi-platform Remote Access Software
Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger. 
 
  
 
Simple and Powerful CL-200-E Utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group CL-200-E modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.

Features

Specifications

Temperature Measurement
Range -10 ~ +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Humidity Measurement
Range 0 ~ 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
TVOC Measurement
Range 0 ppb to 60000 ppb (MEMS Metal Oxide)
Resolution 1 ppb
Accuracy ±15%
Response Time 60 seconds
Warm-up Time 180 seconds
System
Alarm TVOC/RH/Temperature
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Relay Output
Channels 1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
COM Ports
Ports 1 x RS-485
1 x Ethernet
Protocol DCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Ethernet
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
Power
Consumption Non-PoE: 1.9 W (Max.)
PoE: 2.0 W (Max.)
Powered from Terminal Block +12 ~ +48 VDC
Mechanical
Dimensions (mm) Ø 150 x 53 (Ø x H)
Installation Ceiling Mounting/Wall Mounting
Ingress Protection Rating IP20
Environmental
Operating Temperature 0 ~ 50°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

CL-200 Series Environmental sensors & Data Loggers datasheet

 

Applications

 

Indoor or Underground Parking Lot Automatic Monitoring Solution
The air quality automation system for indoor or underground parking lot can use the CL-200 series modules to monitor the health and safity information, such as CO, CO2, temperature, humiditym, dew point, and more...




HCHO (Formaldehyde) Detector Automatic Solution
The HCHO/VOC detector provides an instantaneously warning of toxic formaldehyde, which can be found in a plywood factory, furniture factory and new interior remodelling house commonly.

Recently Viewed Products