HOBO® UX120-017M 4-channel Pulse Input Logger - Expanded Memory

HOBO® UX120-017M 4-channel pulse input logger - expanded memory
£34400

(£412.80 incl VAT)
FREE delivery to UK on orders over £100

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:UX120-017M

Description

The HOBO UX120 Pulse Logger is a highly versatile, 4-channel energy data logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates.

The HOBO UX120 Pulse Logger is available in a standard memory model (UX120-017) capable of 500,000 measurements and an expanded memory version (UX120-017M) capable of over 4,000,000 measurements.

IMPORTANT: Hoboware software is now available as a free download that will suffice for most applications. The PRO Version is available for extra analysis tools and use with a Data Shuttle. For the differences between the FREE and PRO versions, please refer to the BHW-Lite (Hoboware Free DVD & USB Cable) entry in the Recommended Products section (below). The download link is also available on the BHW-LITE Page.

Features

  • Simultaneously measures and records pulse signals, events, state changes, and runtimes
  • Stores up to over 4 million measurements (UX120-017M version), enabling longer deployments with fewer site visits
  • Maximum pulse rate – 120 Hz
  • Pulse input range – 0 to 24VDC
  • Streamlines deployment via a range of start/stop options, logger status LEDs, and high-speed USB 2.0 data offload
  • Works with Power meters including Onset's Energy & Power Meter to measure Power Factor (PF), Reactive Power (VAR), Watt Hours (Wh) and more.

Specifications

 
Inputs:
External Contact Input: Electronic solid state switch closure or logic driven digital signals to 24 V
Maximum Pulse Frequency: 120 Hz
Maximum State, Event, Runtime Frequency: 1 Hz
Bits: 4–32 bits depending on pulse rate and logging interval
Maximum Pulses Per Interval: 7,863,960 (using maximum logging rate)
Driven Logic Signal: Input Low: ≤ 0.4 V; Input High: 3 to 24 V
Absolute Maximum Rating: Maximum Voltage: 25 V DC
Minimum Voltage: -0.3 V DC
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal Weak Pull-Up: 100 KΩ
Input Impedance: Solid state switch closure: 100 KΩ pull up; Driven signal: 4.5 KΩ
Minimum Pulse Width: Contact closure duration: 500 uS; Driven logic signal: 100 uS
Lockout Time: 0 to 1 second in 100 ms steps
Edge Detection: Falling edge, Schmitt Trigger buffer
Preferred Switch State: Normally open or Logic "1" state
Logging:
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A on next page)
Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memory:
Memory UX120-017: 520,192 measurements (assumes 8-bit)
UX120-017M: 4,124,672 measurements (assumes 8-bit)
Download Type USB 2.0 interface
Download Time 30 seconds for UX120-017, 1.5 minutes for UX120-017M
Physical:
Operating Range Logging: -40° to 70°C (-40° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Weight 149 g (5.26 oz)
Size 11.4 x 6.3 x 3.3 cm (4.5 x 2.5 x 1.3 inches)
Environmental Rating IP50
 

 

Applications

For Monitoring:

On its own: Event, Pulse Input, Runtime, State Open/Closed

With CSV-A8: Motor On/Off, 

With Power Meter/Wattnode system: AC Current, AC Voltage, Amp Hour (Ah), Amps (A),  Kilowatt Hours (kWh) , Kilowatts (kW),  Power Factor (PF),  Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W)

Description

The HOBO UX120 Pulse Logger is a highly versatile, 4-channel energy data logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates.

The HOBO UX120 Pulse Logger is available in a standard memory model (UX120-017) capable of 500,000 measurements and an expanded memory version (UX120-017M) capable of over 4,000,000 measurements.

IMPORTANT: Hoboware software is now available as a free download that will suffice for most applications. The PRO Version is available for extra analysis tools and use with a Data Shuttle. For the differences between the FREE and PRO versions, please refer to the BHW-Lite (Hoboware Free DVD & USB Cable) entry in the Recommended Products section (below). The download link is also available on the BHW-LITE Page.

Features

  • Simultaneously measures and records pulse signals, events, state changes, and runtimes
  • Stores up to over 4 million measurements (UX120-017M version), enabling longer deployments with fewer site visits
  • Maximum pulse rate – 120 Hz
  • Pulse input range – 0 to 24VDC
  • Streamlines deployment via a range of start/stop options, logger status LEDs, and high-speed USB 2.0 data offload
  • Works with Power meters including Onset's Energy & Power Meter to measure Power Factor (PF), Reactive Power (VAR), Watt Hours (Wh) and more.

Specifications

 
Inputs:
External Contact Input: Electronic solid state switch closure or logic driven digital signals to 24 V
Maximum Pulse Frequency: 120 Hz
Maximum State, Event, Runtime Frequency: 1 Hz
Bits: 4–32 bits depending on pulse rate and logging interval
Maximum Pulses Per Interval: 7,863,960 (using maximum logging rate)
Driven Logic Signal: Input Low: ≤ 0.4 V; Input High: 3 to 24 V
Absolute Maximum Rating: Maximum Voltage: 25 V DC
Minimum Voltage: -0.3 V DC
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal Weak Pull-Up: 100 KΩ
Input Impedance: Solid state switch closure: 100 KΩ pull up; Driven signal: 4.5 KΩ
Minimum Pulse Width: Contact closure duration: 500 uS; Driven logic signal: 100 uS
Lockout Time: 0 to 1 second in 100 ms steps
Edge Detection: Falling edge, Schmitt Trigger buffer
Preferred Switch State: Normally open or Logic "1" state
Logging:
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A on next page)
Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memory:
Memory UX120-017: 520,192 measurements (assumes 8-bit)
UX120-017M: 4,124,672 measurements (assumes 8-bit)
Download Type USB 2.0 interface
Download Time 30 seconds for UX120-017, 1.5 minutes for UX120-017M
Physical:
Operating Range Logging: -40° to 70°C (-40° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Weight 149 g (5.26 oz)
Size 11.4 x 6.3 x 3.3 cm (4.5 x 2.5 x 1.3 inches)
Environmental Rating IP50
 

 

Technical

Applications

For Monitoring:

On its own: Event, Pulse Input, Runtime, State Open/Closed

With CSV-A8: Motor On/Off, 

With Power Meter/Wattnode system: AC Current, AC Voltage, Amp Hour (Ah), Amps (A),  Kilowatt Hours (kWh) , Kilowatts (kW),  Power Factor (PF),  Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W)