The iSN-711-MRTU module is an intelligent vibration detection device. It has a built-in MEMS accelerometer, so it can easily realize equipment vibration monitoring.
The module supports one RS-485 communication interface with Modbus RTU slave protocol, the user can transmit Modbus RTU commands to read the sensor’s data by RS-485 interface. The iSN-711-MRTU is suitable for real-time vibration detection in critical locations for factory monitoring applications, such as production line equipment, motors, and pumps, etc., where there is a need to monitor any vibration application.
-Acceleration(mg): RMS, Maximum, P-P
-Velocity(mm/s): RMS
-Top 10 spectrum values(Amplitude/Frequency)
-Crest Factor
Vibration Measurement | |
---|---|
Axes | 1 |
Sensor Type | MEMS |
Amplitude Range | ±8g |
Frequency Range | 10 Hz to 1K Hz |
COM Ports | |
---|---|
Ports | 1 x RS-485(D+, D-) |
Baud Rate | 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
Data Format | N, 8, 1 |
Protocol | Modbus RTU |
Power | |
---|---|
Input Range | +10 ~ +30 VDC |
Consumption | 0.3 W |
Mechanical | |
---|---|
Dimensions (mm) | 51 x 30 x 19 (W x L x H) |
Installation | Wall-mount or magnet adsorption |
Environment | |
---|---|
Operating Temperature | -25 °C ~ +75 °C |
Storage Temperature | -30 ~ +80°C |
Humidity | 10 ~ 90% RH, Non-condensing |
The iSN-711-MRTU module is an intelligent vibration detection device. It has a built-in MEMS accelerometer, so it can easily realize equipment vibration monitoring.
The module supports one RS-485 communication interface with Modbus RTU slave protocol, the user can transmit Modbus RTU commands to read the sensor’s data by RS-485 interface. The iSN-711-MRTU is suitable for real-time vibration detection in critical locations for factory monitoring applications, such as production line equipment, motors, and pumps, etc., where there is a need to monitor any vibration application.
Vibration Measurement | |
---|---|
Axes | 1 |
Sensor Type | MEMS |
Amplitude Range | ±8g |
Frequency Range | 10 Hz to 1K Hz |
COM Ports | |
---|---|
Ports | 1 x RS-485(D+, D-) |
Baud Rate | 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
Data Format | N, 8, 1 |
Protocol | Modbus RTU |
Power | |
---|---|
Input Range | +10 ~ +30 VDC |
Consumption | 0.3 W |
Mechanical | |
---|---|
Dimensions (mm) | 51 x 30 x 19 (W x L x H) |
Installation | Wall-mount or magnet adsorption |
Environment | |
---|---|
Operating Temperature | -25 °C ~ +75 °C |
Storage Temperature | -30 ~ +80°C |