100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

MX1102A CO2/Temp/RH Data Logger (Bluetooth)

MX1102A CO2/Temp/RH Data Logger (Bluetooth)
£76100

(£913.20 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:MX1102A

Description

Measures and records CO2 in buildings and other non-condensing environments. Works with our the HOBOconnect app for data access right from your mobile phone, tablet, or Windows computer when within 100 feet of the logger.

This logger also features a USB port so it can be used with a computer running HOBOware graphing & analysis software.

Features

  • Wireless communication via Bluetooth technology
  • Six-month battery life at 5-minute CO2 logging rate
  • Easy to deploy and offload using free HOBOconnect app
  • Visual and audible high & low alarm thresholds
  • Self-calibrating NDIR CO2 sensor technology ensures optimal accuracy and lower maintenance costs
  • Patented connectivity technology

Specifications

Temperature Sensor

Range 0° to 50°C  (32° to 122°F)
Accuracy ±0.21°C from 0° to 50°C, see manual for plot (±0.38°F from 32° to 122°F, see manual for plot)
Resolution 0.024°C at 25°C , see manual for plot 0.04°F at 77°F , see manual for plot
Drift <0.1°C per year 0.18°F per year

RH Sensor*

Range 1% to 90% RH (non-condensing)
Accuracy ±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution 0.01%
Drift <1% per year typical

CO2 Sensor

Range 0 to 5,000 ppm
Accuracy ±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH (non-condensing) and 1,013 mbar
Warm-up Time 15 seconds
Calibration Auto or manual to 400 ppm
Non-linearity <1% of FS
Pressure Dependence 0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range 950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range -305 to 5,486 m ( -1,000 to 18,000 ft)
Sensing Method Non-dispersive infrared (NDIR) absorption

Response Time

Temperature 12 minutes to 90% in airflow of 1 m/s (12 minutes to 90% in airflow of 2.2 mph)
RH 1 minute to 90% in airflow of 1 m/s (1 minute to 90% in airflow of 2.2 mph)
CO2 1 minute to 90% in airflow of 1 m/s (1 minute to 90% in airflow of 2.2 mph)

Logger

Radio Power
1 mW
0 dBm
Transmission Range Approximately 30.5 m line-of-sight (Approximately 100 ft line-of-sight)
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range 0° to 50°C ; 0 to 95% RH (non-condensing), 32° to 122°F ; 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
Logging Modes Fixed interval (normal, statistics) or burst
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, date & time, or after a set logging period
Time Accuracy ±1 minute per month at 25°C  (±1 minute per month at 77°F)
Power Source 4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts)
Battery Life 6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life.
Memory 128 KB (84,650 measurements, maximum)
Download Type USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time 20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger
LCD LCD is visible from 0° to 50°C; 
LCD is visible from 32° to 122°F;
 
the LCD may react slowly or go blank in temperatures outside this range
Size
7.62 x 12.95 x 4.78 cm, 
3.0 x 5.1 x 1.88 inches
Weight
267.4 g , 
9.43 oz
Environmental Rating IP50
*Per RH sensor manufacturer data sheet

 

Description

Measures and records CO2 in buildings and other non-condensing environments. Works with our the HOBOconnect app for data access right from your mobile phone, tablet, or Windows computer when within 100 feet of the logger.

This logger also features a USB port so it can be used with a computer running HOBOware graphing & analysis software.

Features

Specifications

Temperature Sensor

Range 0° to 50°C  (32° to 122°F)
Accuracy ±0.21°C from 0° to 50°C, see manual for plot (±0.38°F from 32° to 122°F, see manual for plot)
Resolution 0.024°C at 25°C , see manual for plot 0.04°F at 77°F , see manual for plot
Drift <0.1°C per year 0.18°F per year

RH Sensor*

Range 1% to 90% RH (non-condensing)
Accuracy ±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution 0.01%
Drift <1% per year typical

CO2 Sensor

Range 0 to 5,000 ppm
Accuracy ±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH (non-condensing) and 1,013 mbar
Warm-up Time 15 seconds
Calibration Auto or manual to 400 ppm
Non-linearity <1% of FS
Pressure Dependence 0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range 950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range -305 to 5,486 m ( -1,000 to 18,000 ft)
Sensing Method Non-dispersive infrared (NDIR) absorption

Response Time

Temperature 12 minutes to 90% in airflow of 1 m/s (12 minutes to 90% in airflow of 2.2 mph)
RH 1 minute to 90% in airflow of 1 m/s (1 minute to 90% in airflow of 2.2 mph)
CO2 1 minute to 90% in airflow of 1 m/s (1 minute to 90% in airflow of 2.2 mph)

Logger

Radio Power
1 mW
0 dBm
Transmission Range Approximately 30.5 m line-of-sight (Approximately 100 ft line-of-sight)
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range 0° to 50°C ; 0 to 95% RH (non-condensing), 32° to 122°F ; 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
Logging Modes Fixed interval (normal, statistics) or burst
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, date & time, or after a set logging period
Time Accuracy ±1 minute per month at 25°C  (±1 minute per month at 77°F)
Power Source 4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts)
Battery Life 6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life.
Memory 128 KB (84,650 measurements, maximum)
Download Type USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time 20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger
LCD LCD is visible from 0° to 50°C; 
LCD is visible from 32° to 122°F;
 
the LCD may react slowly or go blank in temperatures outside this range
Size
7.62 x 12.95 x 4.78 cm, 
3.0 x 5.1 x 1.88 inches
Weight
267.4 g , 
9.43 oz
Environmental Rating IP50
*Per RH sensor manufacturer data sheet

 

Technical

MX1102A Datasheet