To give you the best experience we use cookies. Learn More

OK

100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

PM-3112-100 Smart Power Meter Single Phase, 2 Loops (60A)

PM-3112-100 Smart Power Meter Single phase, 2 loops (60A)
£15700

(£188.40 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:PM-3112-100

Description

The PM-3000 series is a range of powerful and advanced Smart Power Meters that give you access to real-time electric usage for single-phase power measurement.

With its high accuracy (<1%, PF=1 ), the PM-3000 series can obtain reliable and accurate energy consumption readings from the monitored equipment in real time. These compact and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input currents up to 200 A). It operates over a wide input voltage range 10 ~ 300 VAC to allow worldwide compatibility. And with 2 channels of relay outputs, it can be linked with sirens or lights/indicators for alarm messages. They are available in versions supporting Modbus RTU, Modbus TCP or CAN bus protocols for easy integration. For ModbusTCP or CAN, please contact us.

NOTE: Installation must be carried out to any relevant standards by suitably qualified engineers.

Features

  • True RMS Power Measurements
  • Energy Analysis for 1P2W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 300 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 1% (PF=1)
  • Supports RS-485, Ethernet or CAN bus Interface (different models)
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol (different models)
  • Supports 2 Power Relay Output (Form A)

Specifications

AC Power Measurement
Wiring 1P2W-2CT
Loops Single-phase
Input Voltage 10 ~ 300 V
Input Current CTØ10 mm (0.05 A ~ 60 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
CT
Includes CTs 2
Type Clip
Max. Current 60 A
Inside Diameter 10 mm
Leading Cable 1.8 m
COM Ports
Ports 1 x RS-485
Baud Rate 9600, 19200 (default), 38400, 115200; DIP Switch Selectable
Data Format N,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
Protocol Modbus RTU
Isolation 3000 VDC
Power
Input Range +12 ~ 48 VDC
Consumption 2W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VD
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

 

Description

The PM-3000 series is a range of powerful and advanced Smart Power Meters that give you access to real-time electric usage for single-phase power measurement.

With its high accuracy (<1%, PF=1 ), the PM-3000 series can obtain reliable and accurate energy consumption readings from the monitored equipment in real time. These compact and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input currents up to 200 A). It operates over a wide input voltage range 10 ~ 300 VAC to allow worldwide compatibility. And with 2 channels of relay outputs, it can be linked with sirens or lights/indicators for alarm messages. They are available in versions supporting Modbus RTU, Modbus TCP or CAN bus protocols for easy integration. For ModbusTCP or CAN, please contact us.

NOTE: Installation must be carried out to any relevant standards by suitably qualified engineers.

Features

Specifications

AC Power Measurement
Wiring 1P2W-2CT
Loops Single-phase
Input Voltage 10 ~ 300 V
Input Current CTØ10 mm (0.05 A ~ 60 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
CT
Includes CTs 2
Type Clip
Max. Current 60 A
Inside Diameter 10 mm
Leading Cable 1.8 m
COM Ports
Ports 1 x RS-485
Baud Rate 9600, 19200 (default), 38400, 115200; DIP Switch Selectable
Data Format N,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
Protocol Modbus RTU
Isolation 3000 VDC
Power
Input Range +12 ~ 48 VDC
Consumption 2W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VD
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

PM-3000 series Single-Phase Smart Power Meter data sheet

Recently Viewed Products