Description

The iSN-101 Liquid Leak Detection Module is a low-cost intelligent liquid leak detection device that can be used to directly control a Relay Output. No additional conversion module is needed and the iSN-101 can be easily integrated with a variety of monitoring systems to achieve remote alarm and remote device control. The iSN-101 Liquid Leak Detection module can be used to monitor double-core leader cable lengths of up to 500 meters, and can be used with both the extended cable and its included liquid leak detection cable. If liquid is detected, the controller immediately activates the output relay - the normally open, normally closed passive output signal . The module can be easily integrated with other collection hosts connected to the network.

The iSN-101 is suitable for real-time leak detection in critical locations, such as computer room base stations, warehouses, libraries, museums and industrial sites, and also for air handling equipment, refrigeration units, liquid containers, or pump tanks, etc., where there is a need to monitor any leakage of the equipment.


When required, communication with the iSN-101 can be programmed based on the Modbus RTU protocol, with the added benefit that different addresses can be configured via hardware to allow for Modbus RTU communication.

 

Apart from the base product, 3 kit options are available, please select from below for more detail and pricing:
Please note, the /S and /S2 kits have the DC100 cable series, which is not extendable and doesn't have the cable break detection.
That requires the DC100X series, with a DC100X-TR Terminator at the end of the line. 
Please select these from the Recommended products sections at the base of this page.

iSN-101/S with 3m Leader & 1m Liquid detect cable
iSN-101/S
= iSN-101 + 3m leader cable + 1m Liquid Detect Cable

iSN-101/S2 with 3m Leader & 3m Liquid detect cable
iSN-101/S2
= iSN-101 + 3m leader cable + 3m Liquid Detect Cable

iSN-101/S3 with Liquid detect probe
iSN-101/S3 
= iSN-101 + Liquid Detect Probe

 

Features

  • 1-ch Liquid Leak Detection
  • Water Leakage detection triggers and audible alarm
  • A mute button to silence the audible alarm
  • Two LED indicators to display the status of the power and the alarm
  • Relay Output for Water Leakage Alarm
  • Liquid Leak Detection Cable and Extended Cable can be up to 500 meters
  • Sensitivity adjustable detection
  • Supports the DCON and the Modbus RTU Protocols
  • Embedded Dual Watchdog
  • Wide Operating Temperature Range: -25 to +75°C
  • Tiny Form Factor with Easy Screw Mounting

Specifications

EMS Protection
EFT (IEC 61000-4-4) ±4 kV for Power
ESD (IEC 61000-4-2) ±8 kV Air for Random Point
LED Indicators
Status 1 as Power Indicator
1 as Alarm Indicator
System
Alarm For both liquid leak detection and cable-break detection.
Buzzer Yes.
Can be muted by a push button.
Relay Output Signal Relay, Form A x1, SPST
0.25 A @ 250 VAC
0.5 A @ 125 VAC
2 A @ 30 VDC
Liquid Leak Detection
Channels 1
Liquid Type Water, 2uS/cm
Sensor Type Probe for point detection
or Cable for line detection
Max. Cable Length 500 meters
Include Liquid Leak Detection Cable and Extended Cables.
Sensitivity Range 26 KΩ ~ 580 KΩ (adjustable by rotary switch)
Cable-break Detection Yes.
For sense cable CA-LLD-DC100X-Lxxx only.
COM Ports
Ports 1 x RS-485
Baud Rate Software Configuration: 1200 ~ 115200 bps
Data Format (N,8,1), (O,8,1), (E,8,1), (N,8,2)
Protocol Modbus RTU or DCON
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 1.5 W Max.
Mechanical
Dimensions (mm) 83 x 70 x 29 (W x L x H)
Installation Screw Mounting
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80°C
Humidity 10 ~ 90% RH, Non-condensing

 

Applications

The iSN-101 is a leakage detection module used in water pipe leak monitoring in buildings with two working modes.
1. Work with the water sense cable that installed near the possible leaking pipe or area to detect leakage with alarm.
2. Work with the water leakage probe that installed in fixed possible leak locations to detect.
The leakage monitoring is applied to the water pipes, fire pipes and sewage pipes of buildings, as well as the detecting of domestic water, drainage and electric equipment, which can effectively achieve water saving and ensure the safety of living. The iSN-101 can detect leakages, send out signal and alarms, combine with the WISE IoT Edge Controller or TPD/VPD Touch HMI, and to further integrate with the mobile APP or community system.

iSN-101 Liquid Detect Application
iSN-101 Liquid Detect Application 2

Description

The iSN-101 Liquid Leak Detection Module is a low-cost intelligent liquid leak detection device that can be used to directly control a Relay Output. No additional conversion module is needed and the iSN-101 can be easily integrated with a variety of monitoring systems to achieve remote alarm and remote device control. The iSN-101 Liquid Leak Detection module can be used to monitor double-core leader cable lengths of up to 500 meters, and can be used with both the extended cable and its included liquid leak detection cable. If liquid is detected, the controller immediately activates the output relay - the normally open, normally closed passive output signal . The module can be easily integrated with other collection hosts connected to the network.

The iSN-101 is suitable for real-time leak detection in critical locations, such as computer room base stations, warehouses, libraries, museums and industrial sites, and also for air handling equipment, refrigeration units, liquid containers, or pump tanks, etc., where there is a need to monitor any leakage of the equipment.


When required, communication with the iSN-101 can be programmed based on the Modbus RTU protocol, with the added benefit that different addresses can be configured via hardware to allow for Modbus RTU communication.

 

Apart from the base product, 3 kit options are available, please select from below for more detail and pricing:
Please note, the /S and /S2 kits have the DC100 cable series, which is not extendable and doesn't have the cable break detection.
That requires the DC100X series, with a DC100X-TR Terminator at the end of the line. 
Please select these from the Recommended products sections at the base of this page.

iSN-101/S with 3m Leader & 1m Liquid detect cable
iSN-101/S
= iSN-101 + 3m leader cable + 1m Liquid Detect Cable

iSN-101/S2 with 3m Leader & 3m Liquid detect cable
iSN-101/S2
= iSN-101 + 3m leader cable + 3m Liquid Detect Cable

iSN-101/S3 with Liquid detect probe
iSN-101/S3 
= iSN-101 + Liquid Detect Probe

 

Features

Specifications

EMS Protection
EFT (IEC 61000-4-4) ±4 kV for Power
ESD (IEC 61000-4-2) ±8 kV Air for Random Point
LED Indicators
Status 1 as Power Indicator
1 as Alarm Indicator
System
Alarm For both liquid leak detection and cable-break detection.
Buzzer Yes.
Can be muted by a push button.
Relay Output Signal Relay, Form A x1, SPST
0.25 A @ 250 VAC
0.5 A @ 125 VAC
2 A @ 30 VDC
Liquid Leak Detection
Channels 1
Liquid Type Water, 2uS/cm
Sensor Type Probe for point detection
or Cable for line detection
Max. Cable Length 500 meters
Include Liquid Leak Detection Cable and Extended Cables.
Sensitivity Range 26 KΩ ~ 580 KΩ (adjustable by rotary switch)
Cable-break Detection Yes.
For sense cable CA-LLD-DC100X-Lxxx only.
COM Ports
Ports 1 x RS-485
Baud Rate Software Configuration: 1200 ~ 115200 bps
Data Format (N,8,1), (O,8,1), (E,8,1), (N,8,2)
Protocol Modbus RTU or DCON
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 1.5 W Max.
Mechanical
Dimensions (mm) 83 x 70 x 29 (W x L x H)
Installation Screw Mounting
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80°C
Humidity 10 ~ 90% RH, Non-condensing

 

Technical

iSN-101 Liquid Leak Detection Unit Datasheet

Applications

The iSN-101 is a leakage detection module used in water pipe leak monitoring in buildings with two working modes.
1. Work with the water sense cable that installed near the possible leaking pipe or area to detect leakage with alarm.
2. Work with the water leakage probe that installed in fixed possible leak locations to detect.
The leakage monitoring is applied to the water pipes, fire pipes and sewage pipes of buildings, as well as the detecting of domestic water, drainage and electric equipment, which can effectively achieve water saving and ensure the safety of living. The iSN-101 can detect leakages, send out signal and alarms, combine with the WISE IoT Edge Controller or TPD/VPD Touch HMI, and to further integrate with the mobile APP or community system.

iSN-101 Liquid Detect Application
iSN-101 Liquid Detect Application 2

Recently Viewed Products