This site uses cookiesX
Free Shipping
100% Guarantee
Contact Us

  0 View Cart

Cart Contents
There are no items in your cart
UK Freephone:0800 048 1057
Email Us
View Cart 0 Items
Cart Contents
There are no items in your cart
View Product Range ▼

DT9828 High-Precision Thermocouple USB Device

DT9828  High-Precision Thermocouple USB Device
£60500

(£726.00 incl VAT)
FREE delivery to UK on orders over £100

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:DT9828
Delivery to UK Only

Description

The low-cost DT9828 USB DAQ module sets the accuracy benchmark for thermocouple measurements. Combined with the included QuickDAQ ready-to-measure application software, the DT9828 is a powerful temperature data logger.

Features

  • 8 differential analog input channels for thermocouple or voltage measurements
  • Support for B, E, J, K, N, R, S, and T thermocouple types
  • One cold junction compensation (CJC) circuit for all thermocouple inputs
  • Open thermocouple detection
  • 24-bit resolution with sampling rates up to 600 Hz
  • Input range of ±156mV
  • Accuracy of 0.09°C and noise of 0.01°C for thermocouples
  • 4, isolated, TTL digital inputs and 4, isolated, open-collector digital outputs
  • ±500V galvanic isolation to the computer to prevent ground loops
  • Powered by USB
  • Free QuickDAQ application to acquire, analyze, and display data

Specifications

Analog Input
Channels Resolution Max Sample Rate Sampling
8 24-bit 600 S/s Multiplexed
Ranges Isolation
±156 mV ±500 V ch-host
Sensor
Thermocouple RTD Thermistor Voltage
Yes Yes
Analog Output
Channels Resolution Speed
Digital I/O
Channels Counter/Timers Tachometer
8

Description

The low-cost DT9828 USB DAQ module sets the accuracy benchmark for thermocouple measurements. Combined with the included QuickDAQ ready-to-measure application software, the DT9828 is a powerful temperature data logger.

Features

  • 8 differential analog input channels for thermocouple or voltage measurements
  • Support for B, E, J, K, N, R, S, and T thermocouple types
  • One cold junction compensation (CJC) circuit for all thermocouple inputs
  • Open thermocouple detection
  • 24-bit resolution with sampling rates up to 600 Hz
  • Input range of ±156mV
  • Accuracy of 0.09°C and noise of 0.01°C for thermocouples
  • 4, isolated, TTL digital inputs and 4, isolated, open-collector digital outputs
  • ±500V galvanic isolation to the computer to prevent ground loops
  • Powered by USB
  • Free QuickDAQ application to acquire, analyze, and display data

Specifications

Analog Input
Channels Resolution Max Sample Rate Sampling
8 24-bit 600 S/s Multiplexed
Ranges Isolation
±156 mV ±500 V ch-host
Sensor
Thermocouple RTD Thermistor Voltage
Yes Yes
Analog Output
Channels Resolution Speed
Digital I/O
Channels Counter/Timers Tachometer
8

Technical

Show Recently Viewed Products