This site uses cookiesX
Free Shipping
100% Guarantee
Contact Us

  0 View Cart

Cart Contents
There are no items in your cart
UK Freephone:0800 048 1057
Email Us
View Cart 0 Items
Cart Contents
There are no items in your cart
View Product Range ▼

DT9857E-8 USB Dynamic Signal Analyzer: 8 IEPE AI, 24-bit, 105.4 KHz; 2 AO, 32-bit, 216 KHz; 16 DIO; 1 Tachometer

DT9857E-8  USB Dynamic Signal Analyzer: 8 IEPE AI, 24-bit, 105.4 kHz; 2 AO, 32-bit, 216 kHz; 16 DIO; 1 Tachometer
£3,64000

(£4,368.00 incl VAT)
FREE delivery to UK on orders over £100

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:DT9857E-8
Delivery to UK Only

Description

The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements. Eight or sixteen, 24-bit, IEPE (ICP®) sensor inputs are synchronized with a tachometer input, two measurement counters, and a general purpose counter/timer to provide data streams that are matched in time, for field or laboratory use. Two stimulus D/A outputs, each 32-bit resolution, and an 8-bit digital output port are available for dynamic waveform generation and control. This rugged, compact module, available either as an OEM board or steel-encased module, connects via USB making them ideal for many measurement applications.

Features

  • Simultaneous IEPE analog inputs, waveform stimulus analog outputs, tachometer synchronous with input data stream, advanced pre and post triggering, 16 DIO (8 in/8 out), synchronous counter/timers, and Sync Bus for up to 256 A/D channels and 32 D/A channels.
  • All inputs and outputs can be synchronized for measurement data coherence...
    • Supports the ability to return the value of the digital input port, tachometer, measure counters, and general-purpose counter in the analog input data stream, all synchronous with analog input data stream…providing correlation of tachometer or any digital input with analog signals.
  • Eight (DT9857E-08) or sixteen (DT9857E-16) Simultaneous, IEPE inputs, 4mA at 24V compliance, all inputs use 24-bit Delta-Sigma A/D converters for high resolution measurement to 105.4kHz, AC or DC coupling.
  • Two 32-bit D/A converter output channels for stimulus or waveform generation to 216kHz.
  • Start trigger (software, threshold, external, or Sync Bus) for acquiring post-trigger samples; reference trigger for acquiring pre/post trigger samples.
  • Analog threshold trigger on any of the analog input channels to program the threshold value from –10V to +10V.
  • SyncBus connector for synchronizing acquisition and waveform stimulus on up to 16 DT9857E modules
  • External 4.75V to 28V Power Supply

Specifications

ANALOG INPUT
CHANNELS RESOLUTION MAX SAMPLE RATE SAMPLING
Up to 16 24-bit 105.4 kS/s/ch Simultaneous
ISOLATION SNR THD SFDR
94 dB Typ. -110 dB Typ. 118 dBFS Typ.
ANALOG OUTPUT
CHANNELS RESOLUTION SPEED
2 32-bit Up to 216 kS/s/ch
DIGITAL I/O
CHANNELS COUNTER/TIMERS TACHOMETER
16 1
SOFTWARE POWER
OS SUPPORT DRIVERS POWER
Windows® Open Layers® SW Suite External
 

 

Description

The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements. Eight or sixteen, 24-bit, IEPE (ICP®) sensor inputs are synchronized with a tachometer input, two measurement counters, and a general purpose counter/timer to provide data streams that are matched in time, for field or laboratory use. Two stimulus D/A outputs, each 32-bit resolution, and an 8-bit digital output port are available for dynamic waveform generation and control. This rugged, compact module, available either as an OEM board or steel-encased module, connects via USB making them ideal for many measurement applications.

Features

  • Simultaneous IEPE analog inputs, waveform stimulus analog outputs, tachometer synchronous with input data stream, advanced pre and post triggering, 16 DIO (8 in/8 out), synchronous counter/timers, and Sync Bus for up to 256 A/D channels and 32 D/A channels.
  • All inputs and outputs can be synchronized for measurement data coherence...
    • Supports the ability to return the value of the digital input port, tachometer, measure counters, and general-purpose counter in the analog input data stream, all synchronous with analog input data stream…providing correlation of tachometer or any digital input with analog signals.
  • Eight (DT9857E-08) or sixteen (DT9857E-16) Simultaneous, IEPE inputs, 4mA at 24V compliance, all inputs use 24-bit Delta-Sigma A/D converters for high resolution measurement to 105.4kHz, AC or DC coupling.
  • Two 32-bit D/A converter output channels for stimulus or waveform generation to 216kHz.
  • Start trigger (software, threshold, external, or Sync Bus) for acquiring post-trigger samples; reference trigger for acquiring pre/post trigger samples.
  • Analog threshold trigger on any of the analog input channels to program the threshold value from –10V to +10V.
  • SyncBus connector for synchronizing acquisition and waveform stimulus on up to 16 DT9857E modules
  • External 4.75V to 28V Power Supply

Specifications

ANALOG INPUT
CHANNELS RESOLUTION MAX SAMPLE RATE SAMPLING
Up to 16 24-bit 105.4 kS/s/ch Simultaneous
ISOLATION SNR THD SFDR
94 dB Typ. -110 dB Typ. 118 dBFS Typ.
ANALOG OUTPUT
CHANNELS RESOLUTION SPEED
2 32-bit Up to 216 kS/s/ch
DIGITAL I/O
CHANNELS COUNTER/TIMERS TACHOMETER
16 1
SOFTWARE POWER
OS SUPPORT DRIVERS POWER
Windows® Open Layers® SW Suite External
 

 

Technical

Show Recently Viewed Products