To give you the best experience we use cookies. Learn More

OK

100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

DEM06M Door Entrance Module (Master Version)

DEM06M Door Entrance Module (Master version)

FREE delivery to UK on orders over £500

Or phone us for our best price

0800 048 1057

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:DEM06M

Description

Door Entrance Module based on state-of-the-art micro-technology for the continuous monitoring and display of the alarm levels of the PolyGard®2 gas warning systems DGC-06 or sensors.

The DEM-06 Door-Entrance-Module can monitor the alarm situations of the DGC-06 systems via the RS-485 bus. Up to 128 relay information bits can be used via the field bus to control alarm displays and warning outputs, e.g. close access to the danger zone.

In the slave version, the DEM-06 can be connected at any point on the system bus. The module monitors the bus and announces the alarm status via LC text display and LED indication.

In the master version, the DEM-06 can monitor up to 96 digital sensors on the bus as an independent monitoring module and warn by display (LCD, LED) in the event of an alarm.

As an option, alarming via an internal buzzer or external warning means with reset function is also possible. Configuration can be done via the password protected keypad to get level and project independent structure without specific programming knowledge.

Features

  • Especially suitable for monitoring rooms with dangerous gas concentrations such as laboratories, underground garages and car parks
  • Slave version for integration in the DGC-06 system
  • Master version as stand-alone system
  • Logical menu structure in 5 selectable languages
  • Simple, fast commissioning due to pre-configuration with standard parameters
  • Visual alarm and text messages with individually settable message texts
  • Serial interface RS-485 • IP65 version
  • Option: Integrated warning buzzer with reset function internal/external
  • Option: 2x open collector output for warning light and warning horn with rest function internal/external.

Specifications

ELECTRICAL

Power supply 18–28 V DC, reverse polarity protected

Power consumption 
(w/o options)


40 mA, max. (1.0 VA) 
Overvoltage category  I
Alarm relay (2)  250 V AC, 5 A, potential-free, change-over contact (SPDT)
Fault relay (1) 250 V AC, 5 A, potential-free, change-over contact (SPDT)
Transistor output (2) 24 V DC/0,1 A (switching to plus) 
Digital input (2) 24 V DCV, 10 mA (potential-free contact against GND) 
Analog output signal (1) Proportional, overload and short-circuit proof, load ≤ 500 Ohms
4–20 mA = measuring range
2.4–< 4 mA = tolerable underrange
> 20–21.2 mA = tolerable overrange
≤ 2,0 mA = fault
Outgoing line for field bus 24 V DC for max. 10 SB2Units., overload and short-circuit proof, reverse-polarity protected 
Field bus for SB2Unit RS-485 / 19200 Baud (max. cable length 900 m)

VISUALISATION

LC-Display 2 lines, 16 characters each, background highlighted, 2 colours 
Status LED (3) Normal operation-Fault–Alarm
Operation  Menu driven via 6 pushbuttons
 

SERIAL INTERFACE

Transceiver  RS-485 / 19200 Baud 

 

AMBIENT CONDITIONS

Temperature range -10 °C to +50 °C (14 °F to +122 °F)
Humidity range 15–90 % RH non-condensing
Storage temperature -20 °C to +65 °C (-4 °F to 149 °F)
Pressure Range 70-130 kPa

PHYSICAL

Housing type A (standard) and type C (for options)  Polycarbonate
Burning behaviour  UL 94 V2
Housing colour RAL 7032 (light grey) 
Dimensions housing (W x H x D)
• Housing type A
• Housing type C 

94 x 130 x 57 mm (3.7 x 5.12 x 2.24 in.)
130 x 130 x 75 mm (5.12 x 5.12 x 2.95 in.)
Weight Max. 0.6 kg (1.32 lbs)
Protection class (delivery state)* IP65
Installation Wall mounting
Knockouts for cable entry  Standard 1x M20
Connection type Screw-type terminals, 0.25–2.5 mm2

1 If there are changes to the housing it has to be re-evaluated.

OPTIONS

INTERNAL BUZZER

Acoustic pressure  > 85 dB (A) (distance 0.1 m) 
Frequency 2300 Hz ± 300 Hz

OPEN COLLECTOR (2)

Transistor output  24 V DC / 0.1 A, (Plus switching)
Digital input (1) Potential-free contact 1
 

 

REGULATIONS

Directives EMC Directives 2014/30/EU
Low Voltage Directive 2014/35/EU
CE, UKCA

Conformity to:
EN 61010-1:2010
ANSI/UL 61010-1
CAN/CSA-C22.2 No. 61010-1 
Warranty 2 years on device

All specifications were collected under optimal test conditions.
We confirm compliance with the minimum requirements of the applicable standard.

Applications

The DEM-06 is especially designed for the use in underground garages and multi-storey car parks or for room application e.g. laboratories.

Description

Door Entrance Module based on state-of-the-art micro-technology for the continuous monitoring and display of the alarm levels of the PolyGard®2 gas warning systems DGC-06 or sensors.

The DEM-06 Door-Entrance-Module can monitor the alarm situations of the DGC-06 systems via the RS-485 bus. Up to 128 relay information bits can be used via the field bus to control alarm displays and warning outputs, e.g. close access to the danger zone.

In the slave version, the DEM-06 can be connected at any point on the system bus. The module monitors the bus and announces the alarm status via LC text display and LED indication.

In the master version, the DEM-06 can monitor up to 96 digital sensors on the bus as an independent monitoring module and warn by display (LCD, LED) in the event of an alarm.

As an option, alarming via an internal buzzer or external warning means with reset function is also possible. Configuration can be done via the password protected keypad to get level and project independent structure without specific programming knowledge.

Features

Specifications

ELECTRICAL

Power supply 18–28 V DC, reverse polarity protected

Power consumption 
(w/o options)


40 mA, max. (1.0 VA) 
Overvoltage category  I
Alarm relay (2)  250 V AC, 5 A, potential-free, change-over contact (SPDT)
Fault relay (1) 250 V AC, 5 A, potential-free, change-over contact (SPDT)
Transistor output (2) 24 V DC/0,1 A (switching to plus) 
Digital input (2) 24 V DCV, 10 mA (potential-free contact against GND) 
Analog output signal (1) Proportional, overload and short-circuit proof, load ≤ 500 Ohms
4–20 mA = measuring range
2.4–< 4 mA = tolerable underrange
> 20–21.2 mA = tolerable overrange
≤ 2,0 mA = fault
Outgoing line for field bus 24 V DC for max. 10 SB2Units., overload and short-circuit proof, reverse-polarity protected 
Field bus for SB2Unit RS-485 / 19200 Baud (max. cable length 900 m)

VISUALISATION

LC-Display 2 lines, 16 characters each, background highlighted, 2 colours 
Status LED (3) Normal operation-Fault–Alarm
Operation  Menu driven via 6 pushbuttons
 

SERIAL INTERFACE

Transceiver  RS-485 / 19200 Baud 

 

AMBIENT CONDITIONS

Temperature range -10 °C to +50 °C (14 °F to +122 °F)
Humidity range 15–90 % RH non-condensing
Storage temperature -20 °C to +65 °C (-4 °F to 149 °F)
Pressure Range 70-130 kPa

PHYSICAL

Housing type A (standard) and type C (for options)  Polycarbonate
Burning behaviour  UL 94 V2
Housing colour RAL 7032 (light grey) 
Dimensions housing (W x H x D)
• Housing type A
• Housing type C 

94 x 130 x 57 mm (3.7 x 5.12 x 2.24 in.)
130 x 130 x 75 mm (5.12 x 5.12 x 2.95 in.)
Weight Max. 0.6 kg (1.32 lbs)
Protection class (delivery state)* IP65
Installation Wall mounting
Knockouts for cable entry  Standard 1x M20
Connection type Screw-type terminals, 0.25–2.5 mm2

1 If there are changes to the housing it has to be re-evaluated.

OPTIONS

INTERNAL BUZZER

Acoustic pressure  > 85 dB (A) (distance 0.1 m) 
Frequency 2300 Hz ± 300 Hz

OPEN COLLECTOR (2)

Transistor output  24 V DC / 0.1 A, (Plus switching)
Digital input (1) Potential-free contact 1
 

 

REGULATIONS

Directives EMC Directives 2014/30/EU
Low Voltage Directive 2014/35/EU
CE, UKCA

Conformity to:
EN 61010-1:2010
ANSI/UL 61010-1
CAN/CSA-C22.2 No. 61010-1 
Warranty 2 years on device

All specifications were collected under optimal test conditions.
We confirm compliance with the minimum requirements of the applicable standard.

Technical

Door Access Module for Gas Monitoring System Datasheet

Applications

The DEM-06 is especially designed for the use in underground garages and multi-storey car parks or for room application e.g. laboratories.

Recently Viewed Products