Description

The PV-3 data logger is used by installers, householders, renewable energy companies to check PV (photo voltaic) installations. It can record solar irradiation up to 1,500W/m2 (watts per square metre), DC Voltage and DC Current produced by the panel, allowing you to assess the performance of a solar energy installation. The logger will record up to 300 days using the included PSU (power supply unit), data can be downloaded to the free software, Electrosoft and analysed.

The advantage of the Electrocorder products over most others is that our data loggers constantly sample information (recording the Min, Max and Average)over the set period, many other products only take 'snap shots' of what isgoing on and can miss 99.9% of the data that is critical to your analysis.

Kit includes data logger, fused voltage input leads, DC current probe, pyranometer, USB lead, 12Vdc PSU, Electrosoft software and a carry case.

NOTE: Please confirm Current range version require: +/- 10A & +/- 100A or +/- 30A & +/- 300A. For IP65 Case, please see the option in the recommended products section below.

Features

  • Solar irradiance, 0-1500W/m2
  • PV system output Vdc to 300Vdc
  • PV system output Idc to 300Adc (100A or 300A versions available)
  • Complete with Electrosoft energy analysis software
  • Ideal for industrial logging
  • Monitor charging circuits, PV (photovoltaic) cell, DC motor, and
    many other applications
  • Data stored in non-volatile memory
  • Memory capacity of 32,000 (True RMS) values per channel (10bit), up to 300 days continuous recording
  • Selectable averaging period from 1 second to 60 minutes
  • CTs fit around 30mm cables  
  • Voltage Accuracy: 1V – 5V < 2%, 6V – 60V < 1%, 60V – 300V ~2%
  • Current Accuracy: <5% of selected range
  • Irradiance Accuracy: Typically 5% of range
  • CAT Rating: CAT II
  • Recording Standard:EN50160 
  • Environmental Sealing: IP43 as standard, available as IP65/NEMA 12/4 
  • Size & Weight:Metric - 260x180x190mm & 2kg

Specifications

  • Recorded values: Records minimum, average & maximum irradiance, voltage & current
  • Minimum and maximum time resolution: Always 20ms
  • Supplied pyranometer sensor accuracy: ±2% of range
  • Measurement range: 0-1500W/m2
  • Irradiance measurement accuracy: Typically 5% of range
  • Pyranometer input lead length: Metric 5m, Imperial/ English 16’ (feet)
  • Voltage measurement range: 1Vdc to 300Vdc
  • Input impedance: 10MΩ
  • Voltage (DC) measurement accuracy: 1Vdc – 5Vdc < 2%, 6Vdc – 60Vdc < 1%, 60V – 300V ~2%
  • Voltage input lead length: Metric 2m, Imperial/English 6’ (feet)
  • Current measurement range:
    ±10Adc & ±100Adc selectable range or
    ±30Adc & ±300Adc selectable range
  • Current measurement accuracy: <5% of selected range
  • Current input lead length: Metric 1.5 metres; Imperial/English 4’ (feet)
  • Sampling frequency: 800Hz (every 1.25ms)
  • Data recorded: Avg, max & min irradiance, voltage & current values during the averaging period
  • Memory capacity: 192kB able to record 32,000 levels per channel
  • Memory type: Non-volatile SEEPROM
  • Memory - averaging period & duration: 1 sec to 60 mins (1 sec gives 2 hrs logging, 60 min gives 300 days logging)
  • Real-time clock accuracy: Greater than 0.001%
  • Battery life while logging: Unlimited – 12Vdc PSU option & battery backup or 1 day on battery power only
  • Battery type: Unit contains four 9V Alkaline batteries (E-Block, PP3, 1604A)
  • Communications interface type: USB, optically isolated to 5,2kV
  • Environmental (temp & sealing): -10C to +40C or +14°F to +104°F. Sealed to IP43 (Optional IP65, NEMA 12/4)
  • Dimensions & weight: Metric 260 x 180 x 190mm & 2kg Imperial/English - 102 x 72 x 8” & 4lb
  • Standards: Recording - EN50160: 1994 - CAT II

Applications

Testing of Solar PV Installations

Description

The PV-3 data logger is used by installers, householders, renewable energy companies to check PV (photo voltaic) installations. It can record solar irradiation up to 1,500W/m2 (watts per square metre), DC Voltage and DC Current produced by the panel, allowing you to assess the performance of a solar energy installation. The logger will record up to 300 days using the included PSU (power supply unit), data can be downloaded to the free software, Electrosoft and analysed.

The advantage of the Electrocorder products over most others is that our data loggers constantly sample information (recording the Min, Max and Average)over the set period, many other products only take 'snap shots' of what isgoing on and can miss 99.9% of the data that is critical to your analysis.

Kit includes data logger, fused voltage input leads, DC current probe, pyranometer, USB lead, 12Vdc PSU, Electrosoft software and a carry case.

NOTE: Please confirm Current range version require: +/- 10A & +/- 100A or +/- 30A & +/- 300A. For IP65 Case, please see the option in the recommended products section below.

Features

  • Solar irradiance, 0-1500W/m2
  • PV system output Vdc to 300Vdc
  • PV system output Idc to 300Adc (100A or 300A versions available)
  • Complete with Electrosoft energy analysis software
  • Ideal for industrial logging
  • Monitor charging circuits, PV (photovoltaic) cell, DC motor, and
    many other applications
  • Data stored in non-volatile memory
  • Memory capacity of 32,000 (True RMS) values per channel (10bit), up to 300 days continuous recording
  • Selectable averaging period from 1 second to 60 minutes
  • CTs fit around 30mm cables  
  • Voltage Accuracy: 1V – 5V < 2%, 6V – 60V < 1%, 60V – 300V ~2%
  • Current Accuracy: <5% of selected range
  • Irradiance Accuracy: Typically 5% of range
  • CAT Rating: CAT II
  • Recording Standard:EN50160 
  • Environmental Sealing: IP43 as standard, available as IP65/NEMA 12/4 
  • Size & Weight:Metric - 260x180x190mm & 2kg

Specifications

  • Recorded values: Records minimum, average & maximum irradiance, voltage & current
  • Minimum and maximum time resolution: Always 20ms
  • Supplied pyranometer sensor accuracy: ±2% of range
  • Measurement range: 0-1500W/m2
  • Irradiance measurement accuracy: Typically 5% of range
  • Pyranometer input lead length: Metric 5m, Imperial/ English 16’ (feet)
  • Voltage measurement range: 1Vdc to 300Vdc
  • Input impedance: 10MΩ
  • Voltage (DC) measurement accuracy: 1Vdc – 5Vdc < 2%, 6Vdc – 60Vdc < 1%, 60V – 300V ~2%
  • Voltage input lead length: Metric 2m, Imperial/English 6’ (feet)
  • Current measurement range:
    ±10Adc & ±100Adc selectable range or
    ±30Adc & ±300Adc selectable range
  • Current measurement accuracy: <5% of selected range
  • Current input lead length: Metric 1.5 metres; Imperial/English 4’ (feet)
  • Sampling frequency: 800Hz (every 1.25ms)
  • Data recorded: Avg, max & min irradiance, voltage & current values during the averaging period
  • Memory capacity: 192kB able to record 32,000 levels per channel
  • Memory type: Non-volatile SEEPROM
  • Memory - averaging period & duration: 1 sec to 60 mins (1 sec gives 2 hrs logging, 60 min gives 300 days logging)
  • Real-time clock accuracy: Greater than 0.001%
  • Battery life while logging: Unlimited – 12Vdc PSU option & battery backup or 1 day on battery power only
  • Battery type: Unit contains four 9V Alkaline batteries (E-Block, PP3, 1604A)
  • Communications interface type: USB, optically isolated to 5,2kV
  • Environmental (temp & sealing): -10C to +40C or +14°F to +104°F. Sealed to IP43 (Optional IP65, NEMA 12/4)
  • Dimensions & weight: Metric 260 x 180 x 190mm & 2kg Imperial/English - 102 x 72 x 8” & 4lb
  • Standards: Recording - EN50160: 1994 - CAT II

Technical

Applications

Testing of Solar PV Installations