HOBO® U14-001 LCD Temperature/RH Logger

HOBO® U14-001 LCD Temperature/RH Logger
£25000

(£300.00 incl VAT)
FREE delivery to UK on orders over £100

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:U14-001

Description

The HOBO U14 LCD Temperature/Relative Humidity (RH) Data Logger displays and records temperature and humidity conditions. It is well-suited for use in manufacturing, processing, and storage environments where reliable monitoring and documentation of specific temp/RH conditions are critical. Data is offloaded via USB to a PC or Mac computer. An alarm display and built-in relay for use with Onset's Remote Alarm and/or Autodialer accessories assure timely notification of alarm conditions  


IMPORTANT: Hoboware software is now available as a free download that will suffice for most applications. The PRO Version is available for extra analysis tools and use with a Data Shuttle. For the differences between the FREE and PRO versions, please refer to the BHW-Lite (Hoboware Free DVD & USB Cable) entry in the Recommended Products section (below). The download link is also available on the BHW-LITE Page.
 

Features

  • Easily view Temperature/RH values while logging
  • Stores around 43000 measurements
  • Faster USB data download time
  • Improved Temp/RH sensor resolution
  • Real-time display of Temperature and RH
  • Alarm display and output ensure timely notification of out-of-range conditions
  • Two models to choose from - internal Temp/RH or external Temp or Temp/RH
  • Optional Remote Alarm and Autodialer
  • Optional protective case for wet or condensing environments

Specifications

Environmental

  • Operating temperature range -20°C to +50°C, 0 to 100% RH non-condensing
  • Operating relative humidity range 0 to 95%, non-condensing, noncorrosive environment

Logger Capabilities

  • Capacity:
    Temp and RH: 21,500 measurements
    Temp Only: 43,000 measurements
  • Software-selectable sampling intervals: 1 second up to 18 hours, recording times up to 1 year
  • Programmable start time/date
  • Recording modes: Stop when full
  • Launch Modes: Immediate, Delayed
  • Non-volatile EEPROM memory retains data even if batteries fail

LCD

  • Size: 33 x 50.8 mm
  • Displays temperature and relative humidity simultaneously
  • Displays °C or °F (selectable within host software)
  • Displays memory remaining and battery level
  • Displays flashing ALERT for out-of-limits conditions (selectable within host software) and stops flashing on offload or return to normal range.

Alarms

  • High and low set points for both temperature and relative humidity
  • Selectable delays for each set point.
  • Alert conditions reset on offload or return to normal range.
  • Selectable Contact Relay: Normally Closed or Normally Open
  • Contact rating: 48VDC, 1A max
  • Contact resistance: less than 1 Ohm
  • Wire size range is 22AWG to 14AWG
  • 0% Low Battery Range Communications
  • Offloads data to PC or U-Shuttle via USB cable
  • Readout full logger (64K) in less than 30 seconds

Timekeeping

  • Time accuracy: ±1 minute per month at 20°C .

Power

  • 3 AAA Alkaline batteries, user-replaceable

Size/Weight

  • 125 x 92 x 31 mm
  • 170 g with batteries

Internal 12-Bit Temperature Sensor

  • Measurement range: -20°C to 50°C
  • Accuracy: 0.2°C over 0° to 50°C
  • Resolution: 0.03% RH @ 25°C
  • Response time: 15 minutes (to 90% in airflow of 1 m/sec)
  • Temperature Accuracy Drift: Negligible

Internal 12-Bit Relative Humidity Sensor

  • User replaceable
  • Measurement range: 0-100% RH, -20 to 50°C
  • ±2.5% from 10% to 90% RH (typical), to a maximum of ±3.5%
  • Resolution: 0.03% RH @ 25°C
  • Response time to 90%: 2 minutes (to 90% in airflow of 1 m/sec)
  • Accuracy Drift: <2% over 5 years typical
  • Hysteresis: 1% typical

External Sensors
For External Sensor Specifications, see the sensor's user manual.


Battery Life
The batteries will last one year in typical conditions (logging intervals of ≥ 1 minute with weekly offloads and average temperatures greater than 10°C or 50°F). Frequent offloads and/or extreme temperatures will reduce battery life.

At temperatures below freezing (0°C), batteries will typically require replacement every six months. In these conditions the battery level bar graph should be checked regularly

Description

The HOBO U14 LCD Temperature/Relative Humidity (RH) Data Logger displays and records temperature and humidity conditions. It is well-suited for use in manufacturing, processing, and storage environments where reliable monitoring and documentation of specific temp/RH conditions are critical. Data is offloaded via USB to a PC or Mac computer. An alarm display and built-in relay for use with Onset's Remote Alarm and/or Autodialer accessories assure timely notification of alarm conditions  


IMPORTANT: Hoboware software is now available as a free download that will suffice for most applications. The PRO Version is available for extra analysis tools and use with a Data Shuttle. For the differences between the FREE and PRO versions, please refer to the BHW-Lite (Hoboware Free DVD & USB Cable) entry in the Recommended Products section (below). The download link is also available on the BHW-LITE Page.
 

Features

  • Easily view Temperature/RH values while logging
  • Stores around 43000 measurements
  • Faster USB data download time
  • Improved Temp/RH sensor resolution
  • Real-time display of Temperature and RH
  • Alarm display and output ensure timely notification of out-of-range conditions
  • Two models to choose from - internal Temp/RH or external Temp or Temp/RH
  • Optional Remote Alarm and Autodialer
  • Optional protective case for wet or condensing environments

Specifications

Environmental

  • Operating temperature range -20°C to +50°C, 0 to 100% RH non-condensing
  • Operating relative humidity range 0 to 95%, non-condensing, noncorrosive environment

Logger Capabilities

  • Capacity:
    Temp and RH: 21,500 measurements
    Temp Only: 43,000 measurements
  • Software-selectable sampling intervals: 1 second up to 18 hours, recording times up to 1 year
  • Programmable start time/date
  • Recording modes: Stop when full
  • Launch Modes: Immediate, Delayed
  • Non-volatile EEPROM memory retains data even if batteries fail

LCD

  • Size: 33 x 50.8 mm
  • Displays temperature and relative humidity simultaneously
  • Displays °C or °F (selectable within host software)
  • Displays memory remaining and battery level
  • Displays flashing ALERT for out-of-limits conditions (selectable within host software) and stops flashing on offload or return to normal range.

Alarms

  • High and low set points for both temperature and relative humidity
  • Selectable delays for each set point.
  • Alert conditions reset on offload or return to normal range.
  • Selectable Contact Relay: Normally Closed or Normally Open
  • Contact rating: 48VDC, 1A max
  • Contact resistance: less than 1 Ohm
  • Wire size range is 22AWG to 14AWG
  • 0% Low Battery Range Communications
  • Offloads data to PC or U-Shuttle via USB cable
  • Readout full logger (64K) in less than 30 seconds

Timekeeping

  • Time accuracy: ±1 minute per month at 20°C .

Power

  • 3 AAA Alkaline batteries, user-replaceable

Size/Weight

  • 125 x 92 x 31 mm
  • 170 g with batteries

Internal 12-Bit Temperature Sensor

  • Measurement range: -20°C to 50°C
  • Accuracy: 0.2°C over 0° to 50°C
  • Resolution: 0.03% RH @ 25°C
  • Response time: 15 minutes (to 90% in airflow of 1 m/sec)
  • Temperature Accuracy Drift: Negligible

Internal 12-Bit Relative Humidity Sensor

  • User replaceable
  • Measurement range: 0-100% RH, -20 to 50°C
  • ±2.5% from 10% to 90% RH (typical), to a maximum of ±3.5%
  • Resolution: 0.03% RH @ 25°C
  • Response time to 90%: 2 minutes (to 90% in airflow of 1 m/sec)
  • Accuracy Drift: <2% over 5 years typical
  • Hysteresis: 1% typical

External Sensors
For External Sensor Specifications, see the sensor's user manual.


Battery Life
The batteries will last one year in typical conditions (logging intervals of ≥ 1 minute with weekly offloads and average temperatures greater than 10°C or 50°F). Frequent offloads and/or extreme temperatures will reduce battery life.

At temperatures below freezing (0°C), batteries will typically require replacement every six months. In these conditions the battery level bar graph should be checked regularly

Technical

Show Recently Viewed Products