To give you the best experience we use cookies. Learn More

OK

100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

CTV-C 0-100 Amp Split-core AC Current Sensor

CTV-C 0-100 Amp split-core AC current sensor
£17100

(£205.20 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:CTV-C

Description

The CTV-C is a split-core AC current sensor responsive over the range of 0 to 100 amps AC for use with U12 data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.

This sensor is not designed for use with intrinsically-safe (IS) loggers; the moulded-plastic housing is rated for indoor use per UL508

Features

  • UL listed
  • Sensor power induced from line voltage
  • Self-gripping split-core design for fast installation

Specifications

  • Ranges available (AC Amps): 0-20, 0-50, 0-100, 0-200, 0-600
  • Accuracy with H8: ±5.0% of full scale
  • Accuracy with U12: ±4.5% of full scale
  • Response time (from 10% to 90% of amplitude): see table
  • Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
  • Voltage rating: 600 VAC
  • Construction and operating environment: Moulded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable); UL listed.
  • Cable Length: 1.8m cable (6 foot)
  • Dimensions: see table

Notes: AC current sensors are not designed for use with Intrinsically Safe (IS) loggers

 

Part No. Range (Amps AC) Approximate Response Time (milliseconds) Dimensions
Window Outer Length Outer Width Height
CTV-A 0–20 440 2.8 cm x 2.3 cm 1.1 in. x 0.9 in. 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-B 0–50 200 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-C 0–100 100 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-D 0–200 450 3.8 cm x 3.3 cm 1.5 in. x 1.3 in 9.9 cm 3.9 in 11.9 cm 4.7 in 2.8 cm 1.1 in
CTV-E 0–600 490 7.4 cm x 6.4 cm 2.9 in. x 2.5 in 13.5 cm 5.3 in 15.0 cm 5.9 in 2.8 cm 1.1 in

 

Description

The CTV-C is a split-core AC current sensor responsive over the range of 0 to 100 amps AC for use with U12 data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.

This sensor is not designed for use with intrinsically-safe (IS) loggers; the moulded-plastic housing is rated for indoor use per UL508

Features

Specifications

Notes: AC current sensors are not designed for use with Intrinsically Safe (IS) loggers

 

Part No. Range (Amps AC) Approximate Response Time (milliseconds) Dimensions
Window Outer Length Outer Width Height
CTV-A 0–20 440 2.8 cm x 2.3 cm 1.1 in. x 0.9 in. 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-B 0–50 200 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-C 0–100 100 2.8 cm x 2.3 cm 1.1 in. x 0.9 in 7.4 cm 2.9 in 6.6 cm 2.6 in 2.5 cm 1.0 in
CTV-D 0–200 450 3.8 cm x 3.3 cm 1.5 in. x 1.3 in 9.9 cm 3.9 in 11.9 cm 4.7 in 2.8 cm 1.1 in
CTV-E 0–600 490 7.4 cm x 6.4 cm 2.9 in. x 2.5 in 13.5 cm 5.3 in 15.0 cm 5.9 in 2.8 cm 1.1 in

 

Recently Viewed Products