This site uses cookiesX
100% Guarantee & Free Delivery
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

I-7065BD SSR-DC Relay Output And Isolated Digital Input Module(5/4)+LEDs

I-7065BD SSR-DC Relay Output and isolated digital input Module(5/4)+LEDs
£10600

(£127.20 incl VAT)
FREE delivery to UK on orders over £100

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:I-7065BD

Description

The I-7065B provides 4 digital input channels and 5 DC SSR output channels. All digital input channels can be used as 16-bit counters. Additionally, the digital input channels can be selected either as sink- or source-type via wire connections. 


In comparison to electromechanical relays, SSR technology provides a faster response time and greater electrical endurance. The integration of DC SSR technology also eliminates potential for arcing, bounce, and switching noise. The I-7065BD/M-7065BD provides 9 LED indicators that can be used to monitor the status of the digital input and SSR output. There are also options for configuring power-on and safe values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided to enhance noise protection capabilities in industrial environments. The M-7065B supports both the Modbus RTU and DCON protocols, which can be configured via software.

Features

  • I-7065B(D) and M-7065B(D)
    • 4 Digital Input channels and 5 DC SSR Output channels
  • Form A DC Solid State Relay Output
  • No Arcing, No Bounce, and No Switching Noise
  • Sink- and Source-type for Digital Input
  • Digital Input Channels can be used as 16-bit Counters
  • Configurable Power-on Value Settings
  • Configurable Safe Value Settings
  • Dual Watchdog
  • Wide Operating Temperature Range: -25 ~ +75°C

Specifications

I/O Specifications

Models I-7063B/I-7063BD I-7065B/I-7065BD M-7065B/M-7065BD
DC Solid State Relay Output
Channels 3 5
Relay Type DC-SSR (Form A)
Form A
DC-SSR
Operating Voltage Range 3 ~ 30 VDC
Max. Load Current 1 A
Leakage Current 0.1 mA
Min. Operate Time 1 ms
Min. Release Time 1 ms
Dielectric Strength 3500 VDC
Electrical Endurance Long Life, No Arcing, No Bounce, No Switching Noise
Power-on Value Yes
Safe Value Yes
Digital Output
Channels 8 4
Type Dry Contact -
Wet Contact Sink/Source
Wet Contact On Voltage Level +1 VDC Max.
Off Voltage Level +4 ~ 30 VDC
Dry Contact On Voltage Level -
Off Voltage Level -
Effective Distance
for Dry Contact
-
Counters Max. Count 65535 (16-bit)
Max. Input Frequency 100 Hz
Min. Pulse Widt 5 ms
Input Impedance 3 kΩ
Channel-to-Channel Isolation -
Overvoltage Protection ±35 VDC

Unit Specifications

Models I-7063B I-7063BD I-7065B I-7065BD M-7065B M-7065BD
Communication
Interface RS-485
Format (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1)
Baud Rate 1200 ~ 115200 bps
Protocol DCON Modbus RTU, DCON
Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable)
LED Indicator/Display
System LED Indicator Yes, 1 LED as Power/Communication Indicator
I/O LED Indicators - Yes, 11 LEDs as
Digital Input/
Relay Output
Indicators
- Yes, 9 LEDs as
Digital Input/
Relay Output
Indicators
- Yes, 9 LEDs as
Digital Input/Relay
Output Indicators
7-Segment LED Display -
Isolation
Intra-Module Isolation, Field-to-Logic 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal
±8 kV Air for Random Point
EFT (IEC 61000-4-4) ±2 kV for Power Line
Surge (IEC 61000-4-5) -
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 0.5 W 1.0 W 0.6 W 1.0 W 0.6 W 1.0 W
Mechanical
Dimensions (W x L x H) 72 mm x 123 mm x 35 mm
Installation DIN-Rail or Wall Mounting
Environment
Operating Temperature -25 ~ +75°C
Storage Temperature -40 ~ +85°C
Humidity 10 ~ 95% RH, Non-condensing

 

Applications

  • Building Automation
  • Factory Automation
  • Machine Automation
  • Remote Maintenance
  • Remote Diagnosis
  • Testing Equipment

Description

The I-7065B provides 4 digital input channels and 5 DC SSR output channels. All digital input channels can be used as 16-bit counters. Additionally, the digital input channels can be selected either as sink- or source-type via wire connections. 


In comparison to electromechanical relays, SSR technology provides a faster response time and greater electrical endurance. The integration of DC SSR technology also eliminates potential for arcing, bounce, and switching noise. The I-7065BD/M-7065BD provides 9 LED indicators that can be used to monitor the status of the digital input and SSR output. There are also options for configuring power-on and safe values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided to enhance noise protection capabilities in industrial environments. The M-7065B supports both the Modbus RTU and DCON protocols, which can be configured via software.

Features

Specifications

I/O Specifications

Models I-7063B/I-7063BD I-7065B/I-7065BD M-7065B/M-7065BD
DC Solid State Relay Output
Channels 3 5
Relay Type DC-SSR (Form A)
Form A
DC-SSR
Operating Voltage Range 3 ~ 30 VDC
Max. Load Current 1 A
Leakage Current 0.1 mA
Min. Operate Time 1 ms
Min. Release Time 1 ms
Dielectric Strength 3500 VDC
Electrical Endurance Long Life, No Arcing, No Bounce, No Switching Noise
Power-on Value Yes
Safe Value Yes
Digital Output
Channels 8 4
Type Dry Contact -
Wet Contact Sink/Source
Wet Contact On Voltage Level +1 VDC Max.
Off Voltage Level +4 ~ 30 VDC
Dry Contact On Voltage Level -
Off Voltage Level -
Effective Distance
for Dry Contact
-
Counters Max. Count 65535 (16-bit)
Max. Input Frequency 100 Hz
Min. Pulse Widt 5 ms
Input Impedance 3 kΩ
Channel-to-Channel Isolation -
Overvoltage Protection ±35 VDC

Unit Specifications

Models I-7063B I-7063BD I-7065B I-7065BD M-7065B M-7065BD
Communication
Interface RS-485
Format (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1)
Baud Rate 1200 ~ 115200 bps
Protocol DCON Modbus RTU, DCON
Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable)
LED Indicator/Display
System LED Indicator Yes, 1 LED as Power/Communication Indicator
I/O LED Indicators - Yes, 11 LEDs as
Digital Input/
Relay Output
Indicators
- Yes, 9 LEDs as
Digital Input/
Relay Output
Indicators
- Yes, 9 LEDs as
Digital Input/Relay
Output Indicators
7-Segment LED Display -
Isolation
Intra-Module Isolation, Field-to-Logic 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal
±8 kV Air for Random Point
EFT (IEC 61000-4-4) ±2 kV for Power Line
Surge (IEC 61000-4-5) -
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 0.5 W 1.0 W 0.6 W 1.0 W 0.6 W 1.0 W
Mechanical
Dimensions (W x L x H) 72 mm x 123 mm x 35 mm
Installation DIN-Rail or Wall Mounting
Environment
Operating Temperature -25 ~ +75°C
Storage Temperature -40 ~ +85°C
Humidity 10 ~ 95% RH, Non-condensing

 

Applications

Recently Viewed Products