To give you the best experience we use cookies. Learn More

OK

100% Guarantee
View Cart (0)
0800 048 1057
0800 048 1057
Menu ▼

INet-100B 8Diff/16se Analog IP, 8 A/O, 8 Dig I/O Unit (BNC Conn)

iNet-100B 8Diff/16se Analog IP, 8 A/O, 8 Dig I/O Unit (BNC Conn)
£1,20000

(£1,440.00 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:Inet-100B

Description

The Inet 100unit provides 8 differential or 16 single-ended Analog Input channels. It also has 8off Analog outputs and 8 Digital Input/Output bits. Sensor connection is via screw terminals.

Each channel contains signal conditioning amplifiers and can therefore directly attach to sensors such as thermocouples, RTD's, strain gauges, resistance sources, current sources, and voltage sources; and return engineering units (e.g. "Volts","Amps"). These units offer the ability to monitor sensors at rates in the ksamples/second range.

The Inet-100B has 16 BNC connectors which offers an optional type of connection for the Single ended Analog inputs.

Software support is offered within the InstruNet World software, while drivers are available for our Orchestrator SCADA software, along with NI Labview plus DasyLab. An enhanced version of InstruNet World (IW+) can be provided along with the necessary files/demo programs to produce Interfaces in C or VB.

Features

  • High Accuracy Data Acquisition Boxes with software for Windows or Macintosh Computers
  • Each box has 16se/8di 14-bit analog inputs, 8 analog outputs and 8 digital I/O lines
  • Each PCI/Nubus Controller has 10 Counter/Timer channels
  • Reduce sensor cabling runs and noise by placing boxes near sensors and 0-300m away from the host computer
  • Signal Conditioning Amplifiers on each input
  • Direct connection to RTD, Thermocouple, Voltage, Thermistor, Bridge and Strain Gauge Sensors
  • 166ks/sec throughput to RAM or to disk
  • Includes Strip Chart/Oscilloscope software
  • Boxes powered by 32-bit DSP PCI or PC-card
  • Optional Optical Isolation
  • Programmable from C, Visual Basic, TestPoint, HP VEE, DASYLab, Orgin, Microlab and SuperScope II.
  • LabVIEW drivers available
  • Each channel has independently programmable analog filters, intergration time, voltage range, sample rate and digital filters.
  • Returns engineering units
  • Solid Aluminium construction

Specifications

 Analog Inputs

  • Channels : 16 single-ended or 8 Differential, 14-bit 4us a/d
  • Ranges: +/- 5V, +/- 0.6V, +/- 78mV, +/- 8mV
  • Throughput : 166ks/sec max. aggregate
  • SNR: 78dB
  • Linearity : Diff. +/- 1.5LSB; Integral +/- 2 LSB
  • Over Voltage : +/- 15V (power on or off)
  • Impedance : >10Mohm 1%, 3pf
  • Common Mode Voltage : +/- 5V min
  • Common Mode Rejection : +/- 80dB
  • Temp.Drift : Gain: +/- 5ppm/'C of FSR
    Offset: Self-cal'ed to 0
  • Time Stability: Gain: 27ppm/1yr typ
    Offset: Self-cal'ed to 0

Analog Outputs

  • Channels: 8 channels, 8-bit D/A
  • Range: Inet-100/100B: +/-5V @4mA
    Inet-100HC: +/-5V @ 15mA
  • Protection: Short to ground continuous
  • Settling Time: 4us (to +/- 1/2 LSB, +/-5V step)
  • Accuracy: +/- 0.4%
  • Coupling: +/- 20mV Digital Coupling
  • Drift: +/- 10ppm/'C of 5V FSR
    +/- 5uV/'C offset drift
  • Readback: See Voltage Input Accuracy

Digital I/O

  • I/O Lines: 8 non-latching inputs and 8 latching outputs at 8 bi-directional terminals
  • Inputs: VIH = 3.2V min. to 12V max.
    VIL = 1.0V max. to -12V min.
    IIH = -200uA, Vi = 3.2V
    IIL = -0.5mA max.
  • Outputs: VOH = 2V min to 5V max.
    IOH = -0.5mA max.
    IOL = 0.5A max., VO = 1.7V
    IOL = 50mA max., VO = 0.7V

Specific Sensor Accuracies are available on the Brochure.

Other Parameters

  • Output to power other external devices: +5V @ 100mA max.; +12V @ 30mA max.; -12V @ 30mA max.
    NOTE: Care must be taken not to overload these outputs as damage to the controller/computer can occur.
  • Network Utilisation: Occupies 1 physical address in the InstruNet network.
  • Compatibility: All InstuNet Controllers and Network Devices
  • Network Connector: DB-25 male connector (input), DB-25 female connector (output)
  • I/O signals connect to the unit via screw terminals (Inet-100B version : Analog Inputs can also be connected via BNC Connectors)
  • Dimensions: 4.6 x 10.7 x 22.9 cms
  • Operating Temperature : 0 to 70'C
  • Storage Temperature : 0 to 70'C
  • Relative Humidity : Upto 90% (non-condensing)
  • Power consumption: +5V @ 180mA max.
    +12V @ 80mA max.
    -12V @ 80mA max.

Description

The Inet 100unit provides 8 differential or 16 single-ended Analog Input channels. It also has 8off Analog outputs and 8 Digital Input/Output bits. Sensor connection is via screw terminals.

Each channel contains signal conditioning amplifiers and can therefore directly attach to sensors such as thermocouples, RTD's, strain gauges, resistance sources, current sources, and voltage sources; and return engineering units (e.g. "Volts","Amps"). These units offer the ability to monitor sensors at rates in the ksamples/second range.

The Inet-100B has 16 BNC connectors which offers an optional type of connection for the Single ended Analog inputs.

Software support is offered within the InstruNet World software, while drivers are available for our Orchestrator SCADA software, along with NI Labview plus DasyLab. An enhanced version of InstruNet World (IW+) can be provided along with the necessary files/demo programs to produce Interfaces in C or VB.

Features

  • High Accuracy Data Acquisition Boxes with software for Windows or Macintosh Computers
  • Each box has 16se/8di 14-bit analog inputs, 8 analog outputs and 8 digital I/O lines
  • Each PCI/Nubus Controller has 10 Counter/Timer channels
  • Reduce sensor cabling runs and noise by placing boxes near sensors and 0-300m away from the host computer
  • Signal Conditioning Amplifiers on each input
  • Direct connection to RTD, Thermocouple, Voltage, Thermistor, Bridge and Strain Gauge Sensors
  • 166ks/sec throughput to RAM or to disk
  • Includes Strip Chart/Oscilloscope software
  • Boxes powered by 32-bit DSP PCI or PC-card
  • Optional Optical Isolation
  • Programmable from C, Visual Basic, TestPoint, HP VEE, DASYLab, Orgin, Microlab and SuperScope II.
  • LabVIEW drivers available
  • Each channel has independently programmable analog filters, intergration time, voltage range, sample rate and digital filters.
  • Returns engineering units
  • Solid Aluminium construction

Specifications

 Analog Inputs

  • Channels : 16 single-ended or 8 Differential, 14-bit 4us a/d
  • Ranges: +/- 5V, +/- 0.6V, +/- 78mV, +/- 8mV
  • Throughput : 166ks/sec max. aggregate
  • SNR: 78dB
  • Linearity : Diff. +/- 1.5LSB; Integral +/- 2 LSB
  • Over Voltage : +/- 15V (power on or off)
  • Impedance : >10Mohm 1%, 3pf
  • Common Mode Voltage : +/- 5V min
  • Common Mode Rejection : +/- 80dB
  • Temp.Drift : Gain: +/- 5ppm/'C of FSR
    Offset: Self-cal'ed to 0
  • Time Stability: Gain: 27ppm/1yr typ
    Offset: Self-cal'ed to 0

Analog Outputs

  • Channels: 8 channels, 8-bit D/A
  • Range: Inet-100/100B: +/-5V @4mA
    Inet-100HC: +/-5V @ 15mA
  • Protection: Short to ground continuous
  • Settling Time: 4us (to +/- 1/2 LSB, +/-5V step)
  • Accuracy: +/- 0.4%
  • Coupling: +/- 20mV Digital Coupling
  • Drift: +/- 10ppm/'C of 5V FSR
    +/- 5uV/'C offset drift
  • Readback: See Voltage Input Accuracy

Digital I/O

  • I/O Lines: 8 non-latching inputs and 8 latching outputs at 8 bi-directional terminals
  • Inputs: VIH = 3.2V min. to 12V max.
    VIL = 1.0V max. to -12V min.
    IIH = -200uA, Vi = 3.2V
    IIL = -0.5mA max.
  • Outputs: VOH = 2V min to 5V max.
    IOH = -0.5mA max.
    IOL = 0.5A max., VO = 1.7V
    IOL = 50mA max., VO = 0.7V

Specific Sensor Accuracies are available on the Brochure.

Other Parameters

  • Output to power other external devices: +5V @ 100mA max.; +12V @ 30mA max.; -12V @ 30mA max.
    NOTE: Care must be taken not to overload these outputs as damage to the controller/computer can occur.
  • Network Utilisation: Occupies 1 physical address in the InstruNet network.
  • Compatibility: All InstuNet Controllers and Network Devices
  • Network Connector: DB-25 male connector (input), DB-25 female connector (output)
  • I/O signals connect to the unit via screw terminals (Inet-100B version : Analog Inputs can also be connected via BNC Connectors)
  • Dimensions: 4.6 x 10.7 x 22.9 cms
  • Operating Temperature : 0 to 70'C
  • Storage Temperature : 0 to 70'C
  • Relative Humidity : Upto 90% (non-condensing)
  • Power consumption: +5V @ 180mA max.
    +12V @ 80mA max.
    -12V @ 80mA max.

Technical

Instrunet Datasheet

Recently Viewed Products