WISE-5800 Web-enabled Data Logger And Controller

WISE-5800 Web-enabled Data Logger and Controller
£35800

(£429.60 incl VAT)
FREE delivery to UK on orders over £500

100% Money Back
30 Day Guarantee

International Shipping
Over 100 Countries

Model:WISE-5800

Description

The new WISE-5800 is a Web-based intelligent data logger/controller. This exciting new product has a range of powerful features which include:-  remote data logging, automatic logic control and remote monitoring.

Fully user configurable the 5800 can be easily set up with a few clicks using a standard web browser. 
Powerful logic control settings can be initiated with a user-friendly and intuitive web interface allowing users to implement IF-THEN-ELSE control logic in just a few clicks of a mouse.

The 5800 combines remote monitoring and data logging with a fully functional PAC. (Programmable Automation Controller)

The inbuilt controller "Rule Engine" checks whether the rules are valid or not and determine the execution of actions under specific conditions. For example, setting up an I/O channel values, performing scheduled or timer tasks, or sending Email messages or CGI commands under specific conditions.

I/O extension can be achieved using the I-7000 series or the XW plug in modules. NOTE: To change the I-7000 units address and channel settings, you will need to use the DCON utility software on a PC, with the I-7000 connected via a RS485 Converter (e.g. I-7561, which can be found under the Recommended products below).

Features

Data Logging. 
With the inbuilt micro SD card, WISE provides Data Logging of all the real-time I/O data. This data can be sent routinely, or on an event, by FTP or email to the user for further data analysis

IF-THEN-ELSE logic rule execution.
The WISE controller is equipped with a powerful set of user configurable commands in the form of an "IF-THEN-ELSE logic Rule Engine". It offers up to 36 IF-THEN-ELSE rules for users to set up the logic of the controller.
User configurable and simple to use.
WISE provides user-friendly browser accessible user interface for configuration and editing control logic on the controllers.

Built in configuration no additional software required
WISE HMI interface runs on regular Web browsers. To edit control logic, it only requires a browser to be connected to the Web server on WISE controller. No additonal software is required on the target PC.

Supports a wide range of hardware.
Can be easily interfaced with a wide range of available I/O hardware. Including upto 16 I-7000 modules. This range includes analog inputs and outputs, digital I/O and counters.

Support Modbus RTU Slave Module 
WISE can be connected to devices (max. of 10) that support Modbus RTU Slave protocol for I/O monitoring.

Standard Timer and Scheduler functions.
WISE has inbuilt timing and Scheduling functions. Tasks can be executed at scheduled dates and times. In addition timers are available to create distinct time intervals between tasks, or to create time delays.

Email message and CGI command transmission.
WISE supports email messaging and CGI command transmission. These transmissions can are provided by the command set associated with rule engine. As such emails or CGI commands can be sent periodically or as a result of an event.

SMS Notification on Alarm (WISE-5801 only)
WISE is equipped with an SMS alarm message function. The logic rules incorporate commands to send pre-defined SMS messages on an event or at pre-determined intervals.

Remote control facility via SMS (WISE-5801 only)
WISE 5800 can accept SMS messages to trigger tasks such as real-time channel monitoring, channel data modification and logic rule execution.

Recipe function for Group Action operation
Recipe functions are available which enable the execution of pre-set sequences. Recipes can responds to IF-THEN-ELSE logic rules conditions. Different Recipe sets can be edited to meet various requirements for different applications.

Real-time monitoring system status of controllers
WISE supports Modbus TCP/RTU Protocol for users to perform real-time monitoring and control of the controllers using SCADA. In addition, WISE provides an easy to view basic HMI web interface for real-time monitoring. This enables users to obtain important real time system information without additional SCADA software.

Password protection.

The WISE HMI web page offers password protection via the admin.

 

Specifications

 


 

Hardware Specifications

CPU Module
CPU 16-bit CPU
SRAM 768 KB
Flash 512 KB
EEPROM 16 KB
NVRAM 31 Bytes
microSD Expansion Yes, can support 1 or 2 GB microSD
RTC (Real Time Clock) RTC Provide seconds, minutes, hours, date of week/month; month and year
Watchdog Timers Yes (0.8 second)
Communication Ports
Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM 1 RS-232 (Reserved, Unsupported by WISE firmware)
COM 2 RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max.
LED Indicators
System LED Yes (Red)
Ethernet Link LED Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
LED Display -
Hardware Expansion
I/O Expansion Bus Yes
Mechanical
Dimensions (W x H x D) 91 mm x 123 mm x 52 mm
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Ambient Relative Humidity 10 ~ 90% RH (non-condensing)
Power
Protection Power reverse polarity protection
Frame Ground Yes (for ESD Protection)
Input Range +12 ~ +48 VDC
Redundant Power Input Yes
Power Consumption 2.0 W
   
 

Software Specifications

Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Schedules Setup prescheduled routine tasks.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
Recording Periods from every 10 secs to every hour can be set.
Modbus TCP/RTU Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel ON?OFF?ON to OFF?OFF to ON?Change
AI Channel =?>?<?>=?<=(value)
Internal Register
DI Counter =?>?<?>=?<=(value)?Change
Timer Timeout?Not Timeout
Schedule In Range?Out of Range
Rule Status Enable?Disable
THEN / ELSE Actions
DO Channel ON?OFF?Pulse Output (Just for XW-Board)
AO Channel Change the value
Internal Register
DI Counter Reset
Timer Start?Reset
Schedule Enable?Disable
Email Send
CGI Commands
Recipe Execute
Data Logger Start?Stop?One-Time Log
Rule Status Enable?Disable

 

Applications

Remote data logging, montioring and control,  Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Test Equipment, etc.

Description

The new WISE-5800 is a Web-based intelligent data logger/controller. This exciting new product has a range of powerful features which include:-  remote data logging, automatic logic control and remote monitoring.

Fully user configurable the 5800 can be easily set up with a few clicks using a standard web browser. 
Powerful logic control settings can be initiated with a user-friendly and intuitive web interface allowing users to implement IF-THEN-ELSE control logic in just a few clicks of a mouse.

The 5800 combines remote monitoring and data logging with a fully functional PAC. (Programmable Automation Controller)

The inbuilt controller "Rule Engine" checks whether the rules are valid or not and determine the execution of actions under specific conditions. For example, setting up an I/O channel values, performing scheduled or timer tasks, or sending Email messages or CGI commands under specific conditions.

I/O extension can be achieved using the I-7000 series or the XW plug in modules. NOTE: To change the I-7000 units address and channel settings, you will need to use the DCON utility software on a PC, with the I-7000 connected via a RS485 Converter (e.g. I-7561, which can be found under the Recommended products below).

Features

Data Logging. 
With the inbuilt micro SD card, WISE provides Data Logging of all the real-time I/O data. This data can be sent routinely, or on an event, by FTP or email to the user for further data analysis

IF-THEN-ELSE logic rule execution.
The WISE controller is equipped with a powerful set of user configurable commands in the form of an "IF-THEN-ELSE logic Rule Engine". It offers up to 36 IF-THEN-ELSE rules for users to set up the logic of the controller.
User configurable and simple to use.
WISE provides user-friendly browser accessible user interface for configuration and editing control logic on the controllers.

Built in configuration no additional software required
WISE HMI interface runs on regular Web browsers. To edit control logic, it only requires a browser to be connected to the Web server on WISE controller. No additonal software is required on the target PC.

Supports a wide range of hardware.
Can be easily interfaced with a wide range of available I/O hardware. Including upto 16 I-7000 modules. This range includes analog inputs and outputs, digital I/O and counters.

Support Modbus RTU Slave Module 
WISE can be connected to devices (max. of 10) that support Modbus RTU Slave protocol for I/O monitoring.

Standard Timer and Scheduler functions.
WISE has inbuilt timing and Scheduling functions. Tasks can be executed at scheduled dates and times. In addition timers are available to create distinct time intervals between tasks, or to create time delays.

Email message and CGI command transmission.
WISE supports email messaging and CGI command transmission. These transmissions can are provided by the command set associated with rule engine. As such emails or CGI commands can be sent periodically or as a result of an event.

SMS Notification on Alarm (WISE-5801 only)
WISE is equipped with an SMS alarm message function. The logic rules incorporate commands to send pre-defined SMS messages on an event or at pre-determined intervals.

Remote control facility via SMS (WISE-5801 only)
WISE 5800 can accept SMS messages to trigger tasks such as real-time channel monitoring, channel data modification and logic rule execution.

Recipe function for Group Action operation
Recipe functions are available which enable the execution of pre-set sequences. Recipes can responds to IF-THEN-ELSE logic rules conditions. Different Recipe sets can be edited to meet various requirements for different applications.

Real-time monitoring system status of controllers
WISE supports Modbus TCP/RTU Protocol for users to perform real-time monitoring and control of the controllers using SCADA. In addition, WISE provides an easy to view basic HMI web interface for real-time monitoring. This enables users to obtain important real time system information without additional SCADA software.

Password protection.

The WISE HMI web page offers password protection via the admin.

 

Specifications

 


 

Hardware Specifications

CPU Module
CPU 16-bit CPU
SRAM 768 KB
Flash 512 KB
EEPROM 16 KB
NVRAM 31 Bytes
microSD Expansion Yes, can support 1 or 2 GB microSD
RTC (Real Time Clock) RTC Provide seconds, minutes, hours, date of week/month; month and year
Watchdog Timers Yes (0.8 second)
Communication Ports
Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM 1 RS-232 (Reserved, Unsupported by WISE firmware)
COM 2 RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max.
LED Indicators
System LED Yes (Red)
Ethernet Link LED Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
LED Display -
Hardware Expansion
I/O Expansion Bus Yes
Mechanical
Dimensions (W x H x D) 91 mm x 123 mm x 52 mm
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Ambient Relative Humidity 10 ~ 90% RH (non-condensing)
Power
Protection Power reverse polarity protection
Frame Ground Yes (for ESD Protection)
Input Range +12 ~ +48 VDC
Redundant Power Input Yes
Power Consumption 2.0 W
   
 

Software Specifications

Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Schedules Setup prescheduled routine tasks.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
Recording Periods from every 10 secs to every hour can be set.
Modbus TCP/RTU Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel ON?OFF?ON to OFF?OFF to ON?Change
AI Channel =?>?<?>=?<=(value)
Internal Register
DI Counter =?>?<?>=?<=(value)?Change
Timer Timeout?Not Timeout
Schedule In Range?Out of Range
Rule Status Enable?Disable
THEN / ELSE Actions
DO Channel ON?OFF?Pulse Output (Just for XW-Board)
AO Channel Change the value
Internal Register
DI Counter Reset
Timer Start?Reset
Schedule Enable?Disable
Email Send
CGI Commands
Recipe Execute
Data Logger Start?Stop?One-Time Log
Rule Status Enable?Disable

 

Technical

WISE-5800 Data Logger datasheet

Applications

Remote data logging, montioring and control,  Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Test Equipment, etc.