(£603.60 incl VAT)
FREE delivery to UK on orders over £500
100% Money Back
30 Day Guarantee
International Shipping
Over 100 Countries
The DL-1000 is a series of particle and gas measurement modules that can measure the concentration of aerosols in the air, such as: PM2.5, PM1, PM10 and the number of particles (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm). In addition, various fume concentrations related to human health can also be measured. For example: CO/CO2/HCHO/NH3/H2S/TVOC DL-1000 can record data and send alarm when concentration is too high. It can be used to record PM1/2.5/10 + one or more of CO, CO2, HCHO, TVOC, NH3, H2S, Temperature, Humidity and Dew Point information, including date and time stamps, and are able to store up to 180,000downloadable records. Real-time data can be accessed from the DL-1000 series Data Logger from anywhere and at any time using the free Windows software, the iOS App or the Android App, as long as they are connected to the same local network as the Data Logger. Support is provided for popular industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/IoT (Internet of Things) connectivity protocol-MQTT. The DL-1000 series Data Logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system. The DL-1000 series is designed for industrial applications in harsh environments that provides IP43 grade protection approval. The rugged RJ-45 ensures tight, robust connections, and guarantees reliable operation, even for applications that are subject to high vibration and shock.
Multi-platform Remote Access Software
Real-time data from the DL-300 Data Logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the Data Logger.
Supports the MQTT Protocol for IoT Applications
Simple and powerful utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group DL-1000 modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.
Replaceable Filter Patch (FLT-C001)
Generally, the PM2.5 measuring sensor on the market is usually installed in outdoor applications. Because the outdoor air is quite dusty, the measuring channel of PM2.5 sensor is easily clogged by aerosol, resulting in continued alarms for the heavy concentration. Due to the error data from the clogged sensor, this module is returned to the factory for repair. Downtime during the repair period often causes significant cost and losses. In order to solve this problem, ICP DAS design the CL-200 series and DL-1000 series with replaceable patch, FLT-C001, which makes it easy for users to replace them without uninstall the devices. Cost of repair and time can be reduced by this innovated mechanical design.
CPU Module | |
---|---|
Real Time Clock | Yes |
Watchdog Timer | Yes, Module (2.3 sec), Communication (Programmable) |
System | |
---|---|
Security | IP filter (whitelist) and Password (web) |
LED Indicators | |
---|---|
Status |
PWR: Green for normal operation Link: Green for the Ethernet-linked S1 ~ S4: Red for an alarm condition |
Temperature Measurement | |
---|---|
Range | -20 ~ +50°C |
Resolution | 0.1°C |
Accuracy | ±0.6°C |
Humidity Measurement | |
---|---|
Accuracy | ±5% RH |
Range | 0 ~ 100% RH |
Resolution | 0.1% RH |
Life Time | 10 years |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
CO Measurement | |
---|---|
Range | 0 ~ 1000 ppm (Electrochemical) |
Resolution | 1 ppm |
Accuracy | ±5% of measured value |
Response Time | 30 seconds |
Warm-up Time | 60 seconds |
Life Time | 5 years |
PM1/PM2.5/PM10 Measurement | |
---|---|
Range | 0 to 1,000μg/m3 ( Laser Type) |
Resolution | 1μg/m3 |
Accuracy | ± 10% of FSR. |
Response Time | 1 sec |
Warm-up Time | 20 sec |
Life Time | 5 years, Customer has to replace the filter patch. |
Particle | |
---|---|
Sizes | 0.3μm, 0.5μm,,1μm, 2.5μm,,5μm, 10μm |
System | |
---|---|
Alarm |
PM1/PM2.5/PM10 /CO/RH/Temperature/ Real Time Clock |
Real Time Clock | Yes |
Data Logger | Yes, up to 180,000 records |
PhotoMOS Relay Output | PhotoMos Relay × 4, 100 VDC @ 1 A |
COM Ports | |
---|---|
Baud Rate | 1200 ~ 115200 bps |
Protocol | Modbus/RTU(RS-485), Modbus TCP(Ethernet) and MQTT(Ethernet) |
Ethernet | |
---|---|
Ports | 10/100 Base-TX, 8-Pin RJ-45 x1(Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
Power | |
---|---|
Consumption |
PoE: 3.1 W (Max.) Non-PoE: 2.7 W (Max.) |
Powered from PoE | IEEE 802.3af, Class 1 (48 V) |
Powered from Terminal Block | +12 ~+48 VDC |
Mechanical | |
---|---|
Dimensions (mm) | 130 x 210 x 70 (W x L x H) |
Installation | DIN-Rail or Wall Mounting |
Ingress Protection Rating | IP43 |
Environmental | |
---|---|
Operating Temperature | -20 ~ +50°C |
Storage Temperature | -30 ~ +75°C |
Humidity | 10 ~ 90% RH, Non-condensing |
DL-102x series PM1/2.5/10, Temp/RH Data logger datasheet
Please note that not all variants are yet available.
Intelligent Street Lighting in Smart City
The DL-1000 is a series of particle and gas measurement modules that can measure the concentration of aerosols in the air, such as: PM2.5, PM1, PM10 and the number of particles (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm). In addition, various fume concentrations related to human health can also be measured. For example: CO/CO2/HCHO/NH3/H2S/TVOC DL-1000 can record data and send alarm when concentration is too high. It can be used to record PM1/2.5/10 + one or more of CO, CO2, HCHO, TVOC, NH3, H2S, Temperature, Humidity and Dew Point information, including date and time stamps, and are able to store up to 180,000downloadable records. Real-time data can be accessed from the DL-1000 series Data Logger from anywhere and at any time using the free Windows software, the iOS App or the Android App, as long as they are connected to the same local network as the Data Logger. Support is provided for popular industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/IoT (Internet of Things) connectivity protocol-MQTT. The DL-1000 series Data Logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system. The DL-1000 series is designed for industrial applications in harsh environments that provides IP43 grade protection approval. The rugged RJ-45 ensures tight, robust connections, and guarantees reliable operation, even for applications that are subject to high vibration and shock.
Multi-platform Remote Access Software
Real-time data from the DL-300 Data Logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the Data Logger.
Supports the MQTT Protocol for IoT Applications
Simple and powerful utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group DL-1000 modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.
Replaceable Filter Patch (FLT-C001)
Generally, the PM2.5 measuring sensor on the market is usually installed in outdoor applications. Because the outdoor air is quite dusty, the measuring channel of PM2.5 sensor is easily clogged by aerosol, resulting in continued alarms for the heavy concentration. Due to the error data from the clogged sensor, this module is returned to the factory for repair. Downtime during the repair period often causes significant cost and losses. In order to solve this problem, ICP DAS design the CL-200 series and DL-1000 series with replaceable patch, FLT-C001, which makes it easy for users to replace them without uninstall the devices. Cost of repair and time can be reduced by this innovated mechanical design.
CPU Module | |
---|---|
Real Time Clock | Yes |
Watchdog Timer | Yes, Module (2.3 sec), Communication (Programmable) |
System | |
---|---|
Security | IP filter (whitelist) and Password (web) |
LED Indicators | |
---|---|
Status |
PWR: Green for normal operation Link: Green for the Ethernet-linked S1 ~ S4: Red for an alarm condition |
Temperature Measurement | |
---|---|
Range | -20 ~ +50°C |
Resolution | 0.1°C |
Accuracy | ±0.6°C |
Humidity Measurement | |
---|---|
Accuracy | ±5% RH |
Range | 0 ~ 100% RH |
Resolution | 0.1% RH |
Life Time | 10 years |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
CO Measurement | |
---|---|
Range | 0 ~ 1000 ppm (Electrochemical) |
Resolution | 1 ppm |
Accuracy | ±5% of measured value |
Response Time | 30 seconds |
Warm-up Time | 60 seconds |
Life Time | 5 years |
PM1/PM2.5/PM10 Measurement | |
---|---|
Range | 0 to 1,000μg/m3 ( Laser Type) |
Resolution | 1μg/m3 |
Accuracy | ± 10% of FSR. |
Response Time | 1 sec |
Warm-up Time | 20 sec |
Life Time | 5 years, Customer has to replace the filter patch. |
Particle | |
---|---|
Sizes | 0.3μm, 0.5μm,,1μm, 2.5μm,,5μm, 10μm |
System | |
---|---|
Alarm |
PM1/PM2.5/PM10 /CO/RH/Temperature/ Real Time Clock |
Real Time Clock | Yes |
Data Logger | Yes, up to 180,000 records |
PhotoMOS Relay Output | PhotoMos Relay × 4, 100 VDC @ 1 A |
COM Ports | |
---|---|
Baud Rate | 1200 ~ 115200 bps |
Protocol | Modbus/RTU(RS-485), Modbus TCP(Ethernet) and MQTT(Ethernet) |
Ethernet | |
---|---|
Ports | 10/100 Base-TX, 8-Pin RJ-45 x1(Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
Power | |
---|---|
Consumption |
PoE: 3.1 W (Max.) Non-PoE: 2.7 W (Max.) |
Powered from PoE | IEEE 802.3af, Class 1 (48 V) |
Powered from Terminal Block | +12 ~+48 VDC |
Mechanical | |
---|---|
Dimensions (mm) | 130 x 210 x 70 (W x L x H) |
Installation | DIN-Rail or Wall Mounting |
Ingress Protection Rating | IP43 |
Environmental | |
---|---|
Operating Temperature | -20 ~ +50°C |
Storage Temperature | -30 ~ +75°C |
Humidity | 10 ~ 90% RH, Non-condensing |
DL-102x series PM1/2.5/10, Temp/RH Data logger datasheet
Please note that not all variants are yet available.
Intelligent Street Lighting in Smart City