Description

NOTE: Please select required Current Range & Communications protocol variant from the Recommended products section at the base of this page.

It's always difficult but crucial to figure out how much energy is being consumed. The PM-313x series is a powerful, cost-effective, advanced range of Compact Power Meters.

Power Meter CT size With its high accuracy (0.5%, PF=1), the PM-313x series products can be applied both on low voltage primary side and/or medium/high voltage secondary side and enable the users to obtain in real time the reliable and accurate energy consumption readings from the monitored equipment. These compact sized and cost effective Power Meters are equipped with revolutionary wired clip-on CT (various types support input current up to 400A) and standard RS485 Modbus communication protocol for easy deployment. It works with input voltages ranging 10V ~ 500V, supporting a wide range of applications.

The PM-3000 family comes in a full range of Single-phase and Three-phase compact power meters for power monitoring. The products offer a rich feature set combined with easy-to-integrate communications. They can easily be combined with our Data Logging and Data Acquisition products for a complete solution, such as our Orchestrator SCADA softwareGT-540 GPRS Remote Logging unit or the PMC/PMD series of Power Meter Logging units.

The PM-313x series also come with 2 channels of relay outputs, which can be linked with sirens or lights for alarm indication. It supports Modbus RTU protocol (with Modbus TCP or CAN bus) for easy integration.

 

Features

  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Current Measurements Up to 400 A with Different CT Ratio
  • Voltage Measurements Up to 500 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 0.5% (PF=1)
  • Supports RS-485, Ethernet (PoE) or CANopen Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Supports 2 Power Relay Output (Form A)
  • Total Harmonic Distortion (THD)
  • Compatible with PMC/PMD Series Data Loggers/Concentrators/IoT Gateways
 
  • Compatible with PMC/PMD Series Data Loggers/Concentrators/IoT Gateways
  • Compatible with PMC/PMD Series Data Loggers/Concentrators/IoT Gateways

Specifications

Model PM-3133 PM-3133-MTCP PM-3133-CPS
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A); CTØ36 mm (400 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU - -
Baud rate 9600,19200 (default), 38400, 115200; 
DIP Switch Selectable
- -
Data format N,8,1 - -
Isolation 2500 VDC - -
Ethernet (PoE) Protocol - Modbus TCP -
CANopen Protocol - - CAN and CANopen
Baud rate - - 125 k (default), 250 k, 500 k, 
1 M; DIP Switch Selectable
Isolation - - 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC
Power Consumption 4 W
Mechanical
Casing Plastic
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing

 

Technical

PM-3133 3-phase Smart Power Meter Datasheet
 

SOFTWARE:

  1. Use supplied simple utility to record data from a single Meter at a time
  2. Use PMC/PMD Series Power Meter Concentrator/Logging unit (record data from up to 24 Meters), with integrated web Server.
  3. Record in any suitable package using Modbus protocol (Modbus TCP/RTU or CANopen - variant dependant)
  4. Use nModbus functions, which are a C# v3.0 implementation of the modbus commands (DLL's etc)

Description

NOTE: Please select required Current Range & Communications protocol variant from the Recommended products section at the base of this page.

It's always difficult but crucial to figure out how much energy is being consumed. The PM-313x series is a powerful, cost-effective, advanced range of Compact Power Meters.

Power Meter CT size With its high accuracy (0.5%, PF=1), the PM-313x series products can be applied both on low voltage primary side and/or medium/high voltage secondary side and enable the users to obtain in real time the reliable and accurate energy consumption readings from the monitored equipment. These compact sized and cost effective Power Meters are equipped with revolutionary wired clip-on CT (various types support input current up to 400A) and standard RS485 Modbus communication protocol for easy deployment. It works with input voltages ranging 10V ~ 500V, supporting a wide range of applications.

The PM-3000 family comes in a full range of Single-phase and Three-phase compact power meters for power monitoring. The products offer a rich feature set combined with easy-to-integrate communications. They can easily be combined with our Data Logging and Data Acquisition products for a complete solution, such as our Orchestrator SCADA softwareGT-540 GPRS Remote Logging unit or the PMC/PMD series of Power Meter Logging units.

The PM-313x series also come with 2 channels of relay outputs, which can be linked with sirens or lights for alarm indication. It supports Modbus RTU protocol (with Modbus TCP or CAN bus) for easy integration.

 

Features

 

Specifications

Model PM-3133 PM-3133-MTCP PM-3133-CPS
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A); CTØ36 mm (400 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU - -
Baud rate 9600,19200 (default), 38400, 115200; 
DIP Switch Selectable
- -
Data format N,8,1 - -
Isolation 2500 VDC - -
Ethernet (PoE) Protocol - Modbus TCP -
CANopen Protocol - - CAN and CANopen
Baud rate - - 125 k (default), 250 k, 500 k, 
1 M; DIP Switch Selectable
Isolation - - 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC
Power Consumption 4 W
Mechanical
Casing Plastic
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing

 

Technical

PM-3133 3-phase Smart Power Meter Datasheet
 

SOFTWARE:

  1. Use supplied simple utility to record data from a single Meter at a time
  2. Use PMC/PMD Series Power Meter Concentrator/Logging unit (record data from up to 24 Meters), with integrated web Server.
  3. Record in any suitable package using Modbus protocol (Modbus TCP/RTU or CANopen - variant dependant)
  4. Use nModbus functions, which are a C# v3.0 implementation of the modbus commands (DLL's etc)

Recently Viewed Products