Measurement Systems - forefront of the data acquisition market
Username: Password: Buy On-Line   
Products
I-7530 RS232 to CAN Bus Converter £122.00

The I-7530 RS232 to CAN Bus converter makes it possible to connect a host PC/HMI Display into a CAN Bus Network. Similarly it can also allow standard RS232 devices to be connected to a CAN Bus Network.

The PC can be the CAN host, monitor or HMI to access/control the CAN device through the CAN network via the i-7530 Converter. The programmable RS-232 device (For example: i-8411/i-8431/i-8811/i-8831/W-8341/W-8741 embedded controller) can use the serial port to connect to the CAN network via the i-7530 module. The i-7530 is designed to unleash the power of CAN bus via RS-232 communication method. It accurately converts messages between CAN and RS-232 networks. This module allows you to communicate with CAN devices easily from any PC or from any devices with an RS-232 interface.

I-7530 Application

Quantity:     

Features

3000V isolation on CAN side
The CAN port of i-7530 has 3000V isolation. This isolation can protect the local RS-232 devices from the damaging signals coming from the CAN network.

Watchdog inside
The i-7530 Watchdog has a hardware reset circuit to monitor the i-7530’s operation status. When working in harsh or noisy environments, the i-7530 may be affected by the external signal. The circuit will help the i-7530 to continue operating.

Power and Error indicator display
There are two indicators on the i-7530.The power indicator can help user to check whether the i-7530 is in standby or is transmitting/receiving messages. The Error indicator will be turned on when some errors occur on the i-7530.

  • Microprocessor inside with 20MHz
  • CAN interface connector: D-Sub 9-pin
  • 82C250 CAN transceiver
  • Built-in CAN/RS-232 Converter firmware
  • Max transmission speed up to 1M bps for CAN and 115.2K bps for RS-232
  • Software configurable CAN and RS-232 communication parameters
  • Max transmission distance over 1000m (follow CAN specification)
  • Support both CAN 2.0A and CAN 2.0B
  • Build-in jumper to select 120 ohm terminal resistor
  • Mount easily on DIN-rail
  • Power, data flow and error indicator for CAN and RS-232
  • Watchdog inside
  • Support transparent communication mode
  • Provide a group of RS-232 devices a method to be the network system
    (full-duplex communication mode of RS-232 devices is not supported)
  • CAN bus Baud rate configuration
  • CAN acceptance filter configuration
  • CAN 2.0A or 2.0B specific selection
  • RS-232 Baud rate and data bit setting
  • RS-232 responded selection
  • Easy test to transmit/receive CAN messages
  • Setting for I-7530 communication mode (normal mode or pair connection mode)
  • Specifications

  • RS-232 interface connector: D-Sub 9-pin
  • CAN interface connector: D-Sub 9-pin
  • Isolation voltage: 3000Vrms on the CAN side
  • Repeater request: over than 1000m (suggestion)
  • Accessories: One D-Sub 9-pin cable
  • Dimensions: 120mm x 72mm x 34mm
  • Power requirement: Unregulated 10~30 Vdc with protection from power reversals
  • Power consumption: 1W
  • Operating temperature: -25℃ to +75℃
  • Storage temperature: -40℃ to +80℃
  • Communication speed:
    115.2K bps max for RS-232
    1M bps max for CAN
  • Technical

    Quickstart Guide
    User Manual

    Applications

  • Control System
  • Building Automation
  • Factory Automation
  • Distributed data acquisition